SAFETY INFORMATION LOCAL CODES PRODUCT FEATURES LOCATING FIREBOX

3

SAFETY INFORMATION

Continued

1.Do not use this firebox as a wood-burning fireplace. Use only decorative unvented room heaters (log sets).

2.Do not add extra logs or ornaments such as pine cones, vermicu- lite, or rock wool. Using these added items can cause sooting.

3.Use only the provided hood, or appropriate hood accessory. See Accessories, page 14.

4.Vent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly. See Air for Combustion and Ventilation, pages 5 through 7.

5.Do not run vent-free heaters installed in these fireboxes

where flammable liquids or vapors are used or stored

under dusty conditions

6.Do not use this firebox to cook food or burn paper or other objects.

7.Turn unit off and let cool before servicing. Only a qualified service person should service and repair firebox.

8.Operating vent-free heaters installed in these fireboxes above elevations of 4,500 feet could cause pilot outage.

9.Do not use the firebox if it has been under water.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*. Firebox must be electrically grounded in accordance with the National Electrical Code, ANSI/NFPA70 (latest edition).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

OPERATION

This firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room heaters. (Physical size limitations apply. Refer to minimum firebox requirements supplied with log heater.) It requires no outside venting or chimney making installation easy and inexpensive. When used without the blower, the firebox requires no electricity making it ideal for emergency backup heat.

REFRACTORY BRICK LINER

Your firebox features a concrete refractory brick liner. As with all concrete liners, this liner may develop slight cracks when exposed to heat. These cracks will not affect the performance of the fireplace or vent-free gas logs.

LOCATING FIREBOX

PLANNING

Plan where you will install the firebox. This will save time and money later when you install the firebox. Before installation, consider the following:

1.Where the firebox will be located. Allow for wall and ceiling clearances (see Installation Clearances, pages 8 and 9).

2.Everything needed to complete installation.

3.These models CANNOT be installed in a bedroom unless the maximum Btu rating of the installed vent-free log set is less than 10,000 Btu/hr.

4.Proper air for combustion and ventilation (page 5).