Desa (V)DVC36(B)(H) Safety information, Local Codes, Product Identification, Product Features

Models: (V)DVC36(B)(H) (V)DVC42(B)(H)

1 20
Download 20 pages 2.49 Kb
Page 3
Image 3
Safety information

Safety information

Continued

3.You must keep control compartments, burn- ers and circulating air passages clean. More frequent cleaning may be needed due to ex- cessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

4.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired.

5.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

6.This appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

7.Do not use fireplace if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replace- ment of the unit.

8.Do not operate fireplace if any log is broken.

9.Do not operate fireplace with glass door removed, cracked or broken.

10.Provide adequate clearances around air openings.

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur- rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product

Identification

Upper Louver

Flue Collar

Panel

 

Nailing

 

Flange

 

Glass Door

 

Assembly

 

Lower Louver

Panel

Switch Bracket for Optional

Remote and Blower

Figure 1 - Direct-Vent Fireplace

Product Features

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the out- side of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace requires a wall switch, hand-held remote or wall thermostat (millivolt) for opera- tion (see Accessories, page 42).

The use of a blower requires electricity if installed. If you plan to install the blower at a later date, outlet at bottom of fireplace must be wired during framing.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas op- erating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

118197-01Cwww.desatech.com