FIREPLACE MANUFACTURERS INC.

UNVENTED NATURAL GAS LOG HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes veryhotwhenrunningheater.Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow sur- face to cool before touching.

Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (see Installing Damper Clamp Accessory for Vented Operation, page 10).

4.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

5.If fireplace has glass doors, never op- erate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace open- ing has vents at the bottom, you must open the vents before operating heater.

6.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a quali- fied service person. Note: During ini- tial operation, slight smoking may occur due to log curing and heater burning manufacturing residues.

7.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 17.

8.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

9.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 18 through 20.

10.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this heater to cook food or burn paper or other objects.

12.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

13.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger).

2

105072

Page 2
Image 2
Desa VFN18R, VFN30R, VFN24R Fireplace Manufacturers INC Unvented Natural GAS LOG Heater, Safety Information

VFN24R, VFN18R, VFN30R specifications

Desa VFN18R, VFN24R, and VFN30R are a series of innovative heating solutions designed to meet varying heating needs while offering efficiency and reliability. Each model in the VFN range has unique features tailored to residential and commercial applications, contributing to versatile heating solutions.

One of the main characteristics of the VFN series is their impressive heating capacities. The VFN18R model is designed to deliver up to 18,000 BTU/hour, making it suitable for medium-sized spaces. The VFN24R, with its 24,000 BTU/hour output, is ideal for larger areas where more substantial heating is required. Finally, the VFN30R boasts an output of 30,000 BTU/hour, making it a powerful option for substantial heating demands, whether in warehouses, workshops, or expansive living spaces.

These models incorporate advanced technologies to maximize efficiency and performance. Each unit features a high-efficiency heat exchanger designed to produce a more significant amount of heat with lower fuel consumption. This not only translates into cost savings for the user but also reduces environmental impact by minimizing emissions.

In addition, the VFN series is built with a user-friendly interface, making operation straightforward. The units often include programmable thermostats, allowing users to set desired temperatures and schedules, optimizing energy consumption based on specific heating needs. Some models also come with remote control capabilities, offering added convenience.

Safety is a top priority for the VFN models. They come equipped with safety features such as an automatic shut-off system, which activates in case of overheating or malfunction. This contributes to peace of mind, especially in environments with high activity levels or sensitive materials.

The design of the VFN series also enhances their usability and adaptability. These units are compact and can be easily mounted on walls or placed in corners without taking up excessive space. Their aesthetic design allows them to blend seamlessly into different settings, from modern homes to traditional establishments.

In summary, the Desa VFN18R, VFN24R, and VFN30R are versatile heating solutions combining efficiency, safety, and ease of use. With varied heating capacities tailored for different needs and advanced technologies that enhance performance, these models stand out as reliable options for anyone seeking effective heating solutions. Whether for residential comfort or commercial utility, the VFN series delivers on multiple fronts.