FIREPLACE MANUFACTURERS INC.

UNVENTED NATURAL GAS LOG HEATER

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow for Heater Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

105072

Page 4
Image 4
Desa VFN24R, VFN30R AIR for Combustion and Ventilation, Providing Adequate Ventilation, Unusually Tight Construction

VFN24R, VFN18R, VFN30R specifications

Desa VFN18R, VFN24R, and VFN30R are a series of innovative heating solutions designed to meet varying heating needs while offering efficiency and reliability. Each model in the VFN range has unique features tailored to residential and commercial applications, contributing to versatile heating solutions.

One of the main characteristics of the VFN series is their impressive heating capacities. The VFN18R model is designed to deliver up to 18,000 BTU/hour, making it suitable for medium-sized spaces. The VFN24R, with its 24,000 BTU/hour output, is ideal for larger areas where more substantial heating is required. Finally, the VFN30R boasts an output of 30,000 BTU/hour, making it a powerful option for substantial heating demands, whether in warehouses, workshops, or expansive living spaces.

These models incorporate advanced technologies to maximize efficiency and performance. Each unit features a high-efficiency heat exchanger designed to produce a more significant amount of heat with lower fuel consumption. This not only translates into cost savings for the user but also reduces environmental impact by minimizing emissions.

In addition, the VFN series is built with a user-friendly interface, making operation straightforward. The units often include programmable thermostats, allowing users to set desired temperatures and schedules, optimizing energy consumption based on specific heating needs. Some models also come with remote control capabilities, offering added convenience.

Safety is a top priority for the VFN models. They come equipped with safety features such as an automatic shut-off system, which activates in case of overheating or malfunction. This contributes to peace of mind, especially in environments with high activity levels or sensitive materials.

The design of the VFN series also enhances their usability and adaptability. These units are compact and can be easily mounted on walls or placed in corners without taking up excessive space. Their aesthetic design allows them to blend seamlessly into different settings, from modern homes to traditional establishments.

In summary, the Desa VFN18R, VFN24R, and VFN30R are versatile heating solutions combining efficiency, safety, and ease of use. With varied heating capacities tailored for different needs and advanced technologies that enhance performance, these models stand out as reliable options for anyone seeking effective heating solutions. Whether for residential comfort or commercial utility, the VFN series delivers on multiple fronts.