INSTALLATION

Installing Gas Piping To Fireplace Location (Cont.) Connecting Fireplace Insert To Gas Supply

11

INSTALLATION

 

Continued

 

External

 

Regulator

Propane/LP

 

 

Supply

 

Tank

Vent Pointing

 

Down

 

Figure 13 - External Regulator with Vent Pointing Down

Installation must include an equipment shutoff valve, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace insert (see Figure 14).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace insert gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CONNECTING FIREPLACE INSERT TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace insert screen. Lift fireplace insert screen up and pull out to remove.

2.Remove screws that attach log base assembly to fireplace in- sert (see Figure 15). Carefully lift up log base assembly and remove from fireplace insert (see Figure 15).

Note: If adding the G8010 series brick liner accessory, install it now. Follow instructions in G8010 accessory kit.

CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

3.Route gas supply line through access opening of fireplace in- sert (see Figure 15).

CSA Design-Certified

 

Equipment Shutoff Valve

 

With 1/8" NPT Tap*

Supplied Flexible

Propane/LP

Gas Line

From External

 

 

Regulator (11"

 

W.C. to 14" W.C.

 

Pressure)

 

Natural

3" Minimum

From Gas Meter

(5" W.C. to

 

 

10.5" W.C.

 

Pressure)

Cap Pipe

Tee

Nipple

Joint

Sediment Trap

Figure 14 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 30.

Burners

Two Screws

Gas Line

Access

Log Base Assembly

Figure 15 - Removing Log Base Assembly From Fireplace Insert

For morevisit www..com

111285-01B

Page 11
Image 11
Desa VI33NR VI33PR installation manual Connecting Fireplace Insert to GAS Supply, Vent Pointing Down