Desa VI33PRA Wiring Diagrams, Replacement Parts, Service Hints, Specifications, Technical Service

Models: VI33NRA VI33PRA

1 32
Download 32 pages 46.74 Kb
Page 23
Image 23

WIRING DIAGRAMS

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown in Figure 42.

A

 

UTO

OF

O

F

N

 

Thermopile

Figure 42 - Switch Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2 Black

On Blue

Red

110/115

V.A.C.

Black

Green

Blower

White

Motor

Figure 43 - Blower Wiring Diagram

WIRING DIAGRAMS

SPECIFICATIONS 23

REPLACEMENT PARTS

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When calling DESA Inter- national, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP unit, propane/LP gas supply may be low

You may feel your gas pressure is low. If so, contact your local gas supplier.

SPECIFICATIONS

 

VI33NRA

VI33PRA

Btu (Variable)

20,000/30,000

20,000/33,000

Type Gas

Natural Gas Only

Propane/LP Only

Ignition

PiezoPiezo

 

Pressure Manifold

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum*

5"

11"

* For input adjustment

 

 

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical services web site at www.desatech.com.

For morevisit www..com

110150-01A

Page 23
Image 23
Desa VI33PRA, VI33NRA Wiring Diagrams, Replacement Parts, Service Hints, Specifications, Technical Service