INSTALLATION

Installing Blower Accessory GA3450T in Thermostat-Controlled Models (Cont.)

15

INSTALLATION

Continued

Removing Valve Cover Shield

1.Open bottom louver assembly by swinging the assembly down (see Figure 22).

2.Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clock- wise and slide out.

IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 22).

Note: If you do not have a short Phillips screwdriver, the screen, logset, and branch support must be removed so a longer screwdriver may be used. See Removing Upper Louver As- sembly and Branch Support, page 12.

Branch Support

 

Shoulder

 

Screw

Remove

Valve Cover

Screw

Shield

 

 

2

1

Snap Bushings

Bottom Louver Assembly

 

Figure 22 - Removing Valve Cover Shield

Installing Blower Assembly

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

3.Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 23).

4.Carefully disconnect green and white wires at their insulated connectors (see Figure 24).

5.In top of the fireplace cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 23).

6.Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening above where the valve shield was removed. (see Figure 23).

Blower Bracket

Wire Harness

Wiring Routing

Assembly

Hole in Baffle

 

 

 

Blower

Screw

 

Mounting

 

Holes

 

 

Baffle

Switch

 

Power

 

 

Cord

 

3

 

 

2

 

 

1

 

 

Red

Switch

Blue

 

Plate

 

 

 

 

Black

 

 

 

Wire

Valve Cover Shield

Harness

 

 

Box Cover

Figure 23 - Installing Blower Bracket Assembly

Fan Switch

(Auto/Off/On)

1Auto

CAUTION: Verify proper operation after servicing.

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation on page 16.

1. Install snap bushings found in hardware kit into both holes in

rear of valve cover shield.

 

 

Off

2

 

 

 

3

 

 

 

On

110/115

Red

 

V.A.C.

 

 

 

Black

 

 

 

 

 

 

White

 

 

 

Green

 

Blue Thermostat

Switch

(N.O.)

Blue

Blower

Motor

Red

White

Green

2. Make sure the wire harness is firmly connected to the terminals

on the blower bracket assembly.

Figure 24 - Wiring Diagram For Blower Accessory Standard Installation

For morevisit www..com

107032

Page 15
Image 15
Desa VMH10TPB installation manual Removing Valve Cover Shield, Installing Blower Assembly

VMH10TPB specifications

Desa VMH10TPB is a cutting-edge heating solution designed for both residential and commercial applications. This innovative unit is known for its efficiency, advanced technology, and user-friendly features, making it a top choice for consumers looking for reliable heating options.

One of the standout features of the Desa VMH10TPB is its impressive heating capacity. With a maximum output of 10,000 BTUs, this unit is capable of heating spaces effectively, ensuring comfort during the colder months. It is particularly well-suited for areas up to 1,000 square feet, making it ideal for large living rooms, garages, or even small workshops.

The VMH10TPB incorporates advanced infrared heating technology, which provides a more efficient and effective heating experience compared to conventional heaters. Infrared heating warms objects and people directly, rather than just the air, resulting in immediate comfort without the need to wait for the room temperature to rise. This technology also means lower energy costs, as the unit operates at a higher efficiency rate.

Another key characteristic of the Desa VMH10TPB is its ease of use. The unit features a straightforward control panel that allows users to set their preferred temperature with precision. Additionally, it comes with a remote control, providing the convenience of adjusting settings from a distance. This feature is particularly beneficial for those who want to maintain control without having to get up repeatedly.

In terms of safety, the VMH10TPB is equipped with multiple safety features, including an automatic shut-off function and overheating protection. This ensures peace of mind for users, especially in households with children or pets. The durable construction of the unit also adds to its longevity, making it a wise investment for any property owner.

The sleek design of the Desa VMH10TPB allows it to blend seamlessly into various decor styles, whether modern or traditional. Its compact size makes it easy to install and relocate, providing flexibility in heating arrangements.

In conclusion, the Desa VMH10TPB is a powerful and efficient heating solution that combines advanced heating technology with user-friendly features and robust safety measures. With its high output capacity, infrared heating efficiency, and thoughtful design, it is a standout choice for anyone in need of reliable and effective heating.