CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 19).

2.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 20). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

ShutoffOpen

Valve

Closed

Figure 19 - Equipment Shutoff Valve

Gas Meter

Figure 20 - Checking Gas Joints

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 19).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 20). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 and 15). Check all other in- ternal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 14).

8.Replace front panel.

Thermostat Gas

Valve Location

Equipment

Shutoff

Valve

107097

13

For more information, visit www.desatech.com

Page 13
Image 13
Desa VMH3000TNA installation manual Checking GAS Connections, Pressure Testing Gas Supply Piping System

VMH3000TNA specifications

The Desa VMH3000TNA is an advanced heating unit designed for residential and commercial use, providing a reliable source of warmth during colder months. This versatile heater offers a blend of efficiency, modern technology, and user-friendly features, making it a popular choice for consumers seeking comfort and practicality.

One of the standout features of the VMH3000TNA is its high heat output capability. With an impressive heating output of up to 30,000 BTUs, this heater can efficiently warm large spaces, ensuring that any room or area is kept at a comfortable temperature. This makes it an ideal choice for homes, workshops, and even smaller commercial settings.

In terms of technology, the Desa VMH3000TNA is equipped with a reliable electronic ignition system, which eliminates the need for manual lighting and improves overall convenience. This feature is especially beneficial during cold weather, as it ensures quick and effortless operation. Additionally, the heater includes adjustable thermostatic controls, allowing users to set their desired temperature and maintain it with precision.

The heating unit operates using either natural gas or propane, providing flexibility depending on the availability of fuel sources. This adaptability is particularly advantageous for users in remote areas where one fuel type may be more accessible than the other. Furthermore, the VMH3000TNA boasts an energy-efficient design, which helps to reduce operational costs while minimizing environmental impact.

Safety is a critical aspect of the Desa VMH3000TNA's design. It incorporates an automatic shut-off feature, which activates in the event of a malfunction or airflow blockage. This ensures user safety and peace of mind, making it suitable for use in various settings, from homes to commercial spaces. Moreover, the heater is equipped with a durable casing and high-quality components, ensuring longevity and reliability.

Another notable characteristic of this unit is its sleek and contemporary design. The VMH3000TNA features a stylish appearance that can seamlessly fit into a range of interior decors, making it not just a functional appliance but also an aesthetic addition to any room.

In summary, the Desa VMH3000TNA stands out as a powerful, efficient, and user-friendly heating solution. With its high output, modern technologies, versatile fuel options, and safety features, it provides an excellent choice for those seeking dependable heating for their spaces. Whether for a home or a commercial setting, this heater promises to deliver warmth and comfort throughout the cold seasons.