Desa VN10T Inspecting Burner, Cleaning And Maintenance, Pilot Flame Pattern, Burner Flame Pattern

Models: VN10T

1 20
Download 20 pages 61.87 Kb
Page 11
Image 11
INSPECTING

OWNER’S MANUAL

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pat- tern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Pilot Burner

Thermocouple

GOOD PILOTGRH/OV 009

Figure 17 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOTGRH/OV 010

Figure 18 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 18

turn heater off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, pages 12 through 14

BURNER FLAME PATTERN

Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern.

Figure 19 - Correct Burner Flame Pattern

Figure 20 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, pages 12 through 14

CLEANING AND MAINTENANCE

PILOT FLAME PATTERN WARNING: Turn off heater and let cool before cleaning.

BURNER FLAME PATTERN CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.