OWNER’S MANUAL

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _________________ cu. ft. (volume of space)

Example: Space size 18 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2304 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2304 cu. ft. (volume of space) ÷ 50 cu. ft. = 46.1 or 46,100 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater ______________________ Btu/Hr

Gas water heater* ____________________ Btu/Hr

Example:

 

 

 

Gas furnace _________________________ Btu/Hr

Gas water heater

 

40,000

Btu/Hr

Vented gas heater _____________________ Btu/Hr

Vent-free heater

+

10,000

Btu/Hr

Gas fireplace logs ____________________ Btu/Hr

 

=

 

 

Total

50,000

Btu/Hr

Other gas appliances*

+ _______________ Btu/Hr

 

 

 

 

Total

= _______________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_____________ Btu/Hr (maximum the space can support)

_____________ Btu/Hr (actual amount of Btu/Hr used)

Example: 46,100 Btu/Hr (maximum the space can support) 50,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

104086

5

Page 5
Image 5
Desa VN10TA installation manual AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Heater Location

VN10TA specifications

Desa VN10TA is an advanced multi-functional agricultural tractor designed for a wide range of farming tasks. This powerful machine is engineered to meet the needs of modern agriculture, combining efficiency, durability, and versatility into one cohesive package.

One of the standout features of the Desa VN10TA is its robust engine. Equipped with a high-performance diesel engine, it delivers impressive horsepower while ensuring fuel efficiency. The engine is designed with advanced fuel injection technology, optimizing power output and reducing emissions, making it compliant with current environmental standards. This results in lower operating costs for farmers without compromising performance.

The VN10TA also comes with a hydrostatic transmission system, allowing for smoother operation and easier handling. This system provides seamless speed adjustments and enhances maneuverability, particularly in tight spaces. Operators can easily navigate through various terrains, whether working on flat fields or uneven landscapes. The intuitive controls make it user-friendly, ensuring that even those with limited experience can operate it effectively.

In terms of build quality, the Desa VN10TA is constructed with durable materials, ensuring longevity even under harsh working conditions. The chassis is designed to withstand rigorous use while providing stability and balance. This makes it ideal for both heavy-duty tasks and lighter agricultural activities.

Another significant characteristic of the VN10TA is its adaptability to various attachments and implements. The tractor can be equipped with a variety of tools, ranging from plows and harrows to seeders and trailers. This versatility allows farmers to customize their machines based on specific needs, optimizing productivity throughout the growing season.

Incorporating cutting-edge technology, the Desa VN10TA is equipped with an advanced monitoring system. This system provides real-time data regarding engine performance, fuel consumption, and maintenance needs, allowing for proactive management of the tractor. Additionally, the model features ergonomic seating and a spacious cabin, enhancing operator comfort during long hours of work.

Overall, the Desa VN10TA is a reliable and efficient solution for modern agricultural challenges. Its powerful engine, advanced transmission, build quality, and versatility make it an asset to any farming operation, helping to improve productivity and reduce labor costs in the field. Whether for small farms or larger agricultural enterprises, the VN10TA is positioned to meet the evolving demands of the industry.