22
TROUBLE- SHOOTING
Continued
OBSERVED | POSSIBLE |
|
|
| |
PROBLEM | CAUSE | REMEDY | |||
|
|
|
|
|
|
ODS/pilot lights but | 1. | Control knob not fully | 1. | Press in control knob | |
flame goes out when |
| pressed in |
| fully | |
control knob is | 2. | Control knob not | 2. | After ODS/pilot lights, | |
released |
| pressed in long enough |
| keep control knob | |
|
|
|
| pressed in 10 seconds | |
| 3. Manual shutoff valve | 3. | Fully open manual | ||
|
| not fully open |
| ||
| 4. Thermocouple connec- | 4. | Hand tighten until | ||
|
| tion loose at control |
| snug, then tighten 1/4 | |
|
| valve |
| turn more | |
| 5. | Pilot flame not touch- | 5. | A) Contact local | |
|
| ing thermocouple, |
| propane gas company | |
|
| which allows thermo- |
|
|
|
|
| couple to cool, causing |
| B) Clean ODS/pilot | |
|
| pilot flame to go out. |
| (see Cleaning and | |
|
| This problem could be |
| Maintenance, page 20) | |
|
| caused by one or both |
| or replace ODS/pilot | |
|
| of the following: |
| assembly | |
|
| A) Low gas pressure |
|
|
|
|
| B) Dirty or partially |
|
|
|
|
| clogged ODS/pilot |
|
|
|
| 6. Thermocouple dam- | 6. | Replace thermocouple | ||
|
| aged |
|
|
|
| 7. Control valve damaged | 7. | Replace control valve | ||
|
|
|
|
|
|
Burner(s) does not | 1. | Burner orifice(s) is | 1. | Clean burner orifice(s) | |
light after ODS/pilot |
| clogged |
| (see Cleaning and | |
is lit |
|
|
| Maintenance, page 20) | |
|
|
|
| or replace burner | |
|
|
|
| orifice(s) | |
| 2. | Burner orifice(s) | 2. | Replace burner orifice(s) | |
|
| diameter is too small |
|
|
|
| 3. | Inlet gas pressure is | 3. | Contact local propane | |
|
| too low |
| gas company | |
|
|
|
|
|
|
Delayed ignition of | 1. | Manifold pressure is | 1. | Contact local propane | |
burner(s) |
| too low |
| gas company | |
| 2. | Burner orifice(s) is | 2. | Clean burner orifice(s) | |
|
| clogged |
| (see Cleaning and | |
|
|
|
| Maintenance, page 20) | |
|
|
|
| or replace burner | |
|
|
|
| orifice(s) | |
|
|
|
|
|
|
Burner backfiring | 1. | Burner orifice(s) is | 1. | Clean burner orifice(s) | |
during combustion |
| clogged or damaged |
| (see Cleaning and | |
|
|
|
| Maintenance, page 20) | |
|
|
|
| or replace burner | |
|
|
|
| orifice(s) | |
| 2. Burner damaged | 2. | Replace burner | ||
| 3. | Gas regulator defective | 3. | Replace gas regulator |
100844