Desa VP5B, VP11A Trouble- Shooting, Continued, see Cleaning and, Maintenance, page

Models: VP5B VP11A

1 28
Download 28 pages 59.56 Kb
Page 22
Image 22
TROUBLE- SHOOTING

22

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 10 seconds

 

3. Manual shutoff valve

3.

Fully open manual

 

 

not fully open

 

shut-off valve

 

4. Thermocouple connec-

4.

Hand tighten until

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

valve

 

turn more

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

ing thermocouple,

 

propane gas company

 

 

which allows thermo-

 

 

 

 

 

couple to cool, causing

 

B) Clean ODS/pilot

 

 

pilot flame to go out.

 

(see Cleaning and

 

 

This problem could be

 

Maintenance, page 20)

 

 

caused by one or both

 

or replace ODS/pilot

 

 

of the following:

 

assembly

 

 

A) Low gas pressure

 

 

 

 

 

B) Dirty or partially

 

 

 

 

 

clogged ODS/pilot

 

 

 

 

6. Thermocouple dam-

6.

Replace thermocouple

 

 

aged

 

 

 

 

7. Control valve damaged

7.

Replace control valve

 

 

 

 

 

 

Burner(s) does not

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

light after ODS/pilot

 

clogged

 

(see Cleaning and

is lit

 

 

 

Maintenance, page 20)

 

 

 

 

or replace burner

 

 

 

 

orifice(s)

 

2.

Burner orifice(s)

2.

Replace burner orifice(s)

 

 

diameter is too small

 

 

 

 

3.

Inlet gas pressure is

3.

Contact local propane

 

 

too low

 

gas company

 

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local propane

burner(s)

 

too low

 

gas company

 

2.

Burner orifice(s) is

2.

Clean burner orifice(s)

 

 

clogged

 

(see Cleaning and

 

 

 

 

Maintenance, page 20)

 

 

 

 

or replace burner

 

 

 

 

orifice(s)

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice(s) is

1.

Clean burner orifice(s)

during combustion

 

clogged or damaged

 

(see Cleaning and

 

 

 

 

Maintenance, page 20)

 

 

 

 

or replace burner

 

 

 

 

orifice(s)

 

2. Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

100844

Page 22
Image 22
Desa VP5B, VP11A installation manual Trouble- Shooting, Continued, see Cleaning and, Maintenance, page