Image 24
TECHNICAL

TROUBLE-

SHOOTING

Continued

TECHNICAL

SERVICE

SPECIFICATIONS

24

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position

 

top of page

 

Connections,

 

 

 

 

page 14)

 

2.

Control valve defec-

2.

Replace control valve

 

 

tive

 

 

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

1.

Take apart gas tubing

combustion

 

tween control valve

 

and remove foreign

 

 

and burner

 

matter

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

ing statement at

 

leaks (see Checking

 

 

top of page

 

Gas Connections,

 

 

 

 

page 14)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VP11A

VP5B

BTU (Variable)

5,500/11,000

5,500

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

14"

14"

Minimum

11"

11''

Dimensions, Inches (H x W x D)

 

 

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

 

Heater

14

13

Shipping

17

16

100844