Desa (V)PN36-A manual Venting Installtion, Chimney Maintenance, Roof Opening Chart, Continued

Models: (V)PN36-A

1 20
Download 20 pages 60.97 Kb
Page 11
Image 11
VENTING INSTALLTION

FINISHING YOUR CHIMNEY SYSTEM

11

Maximum Chimney Height (Cont.)

Chimney Maintenance

VENTING INSTALLTION

Continued

 

 

 

Chimney Maintenance

 

 

 

WARNING: Do not operate an unvented gas log

Have your chimney system cleaned and inspected regularly to

set in this fireplace with the chimney removed.

ensure safe and efficient operation.

 

RTL-12D

RTL-12D

STL-12D

Using Figure 24 and the roof opening chart below, determine the

Storm

 

 

opening that will be required for the pitch of your particular roof.

 

 

 

 

 

 

 

Collar

 

 

Roof Opening Chart

 

 

 

Flashing

 

 

 

 

 

 

 

PITCH

Opening “A”

Use Flashing

 

 

 

 

 

 

(degrees)

Max. (inches)

Model Number

 

MINIMUM

 

FLAT

19

 

V6F-10DM

 

 

 

 

 

 

 

Firestop

HEIGHT

 

0-6/12

23

1

/4

V6F-10DM

15 FT.

 

 

Spacer

(4.5m)

 

(26.6 deg. Slope)

 

 

 

 

 

 

 

6/12-12/12

30 3/4

V12F-10DM

 

 

 

(56.3 deg. Slope)

 

 

 

 

 

 

MAXIMUM

 

 

 

 

 

 

 

HEIGHT

 

 

 

 

 

 

 

CHASE

 

 

 

 

 

 

 

TERMINATION

 

 

 

 

 

 

40 FT.

 

 

 

 

 

 

 

(12m)

19" Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(48.26cm)

 

 

 

 

 

 

 

 

2" Min.

 

 

 

 

 

 

 

(5.08cm)

 

 

30" Min.

 

 

 

 

 

 

 

(76.2cm)

 

 

Firestop

 

 

 

 

2" Min.

 

 

 

 

 

 

(5.08cm)

 

 

Spacer

 

 

 

 

 

 

 

 

 

2" Min.

 

 

 

 

 

 

 

(5.08cm)

 

 

 

 

 

30°

 

 

 

 

 

 

 

Firestop

 

 

 

 

Opening

 

 

Spacer

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

Figure 25 - Roof Opening

 

 

 

 

30° Offset/

 

Before cutting hole, temporarily remove shingles around area to be

 

Return

 

opened. After preparing the opening on the roof, continue to add

 

 

 

sections of pipe until it extends a minimum of 30 inches above

 

 

 

highest point of roof cutout (see Figure 25).

 

 

 

 

With the termination, the minimum height should add up to 3 feet

 

 

 

(see 10-Foot Rule and Figure 22, page 10).

 

Figure 24 - Maximum Chimney Height

Chimney MaintenanceRoof Opening ChartManual backgroundManual backgroundFor more information, visit www.desatech.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

115607-01A

Page 11
Image 11
Desa (V)PN36-A manual Venting Installtion, Chimney Maintenance, Roof Opening Chart, Continued