16

INSTALLATION

Installing Logs (Cont.)

INSTALLATION

Continued

Models VRL24NR, VRL24PR, VRL30NR, VRL30PR, VRL24NT, VRL24PT, VRL30NT and VRL30PT

1.Place log #1 (ember bed) onto base over log alignment screws to the left of front burner and behind middle burner. Log #1 will sit on top of front and middle burners (see Figure 24).

2.Place log #2 to right of log #1 and onto two log alignment screws as shown in Figure 25. Log #2 will wrap around right end of rear burner (see Figure 25).

3.Place log #3 on left side of base and over alignment screw shown in Figure 25 to left of rear burner. Log #3 will wrap around left end of rear burner.

4.Place log #4 onto two alignment screws to rear of base (see Figure 26).

5.Locate hole on bottom of log #5 and place over pin in rear of ember bed (log #1). Log #5 will rest on log #2 and log #4 as well (see Figure 27)

6.Place log #6 onto two pin on log #1 (ember bed) and rest back of log #6 on back log #4 (see Figure 27).

Log #1

Log #3

Log #2

Log #1

Figure 25 - Installing Log #2 (Right) and Log #3 (Left) [Model VRL30NR Shown]

Log #4

Log #3

Log #2

Log #1

Figure 26 - Installing Log #4 (Model VRL30NR Shown)

Log #5

Figure 24 - Installing Log #1 (Ember Bed)

[Model VRL30NR Shown]

Log #6

Log #4

Log #3

Log #2

Log #1

Figure 27 - Installing Log #5 and Log #6

[Model VRL30NR Shown]

For..com

110021-01A

Page 16
Image 16
Desa CSG3924NT, VRL24NT, CTB3924PT, VRL24PT, VRL30NT, VRL30PT Installing Log #2 Right and Log #3 Left Model VRL30NR Shown

VRL30NT, VRL24PT, CSG3924NT, VRL30PT, VRL24NT specifications

Desa VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT, CTB3924NT, and CTB3924PT are a series of innovative heating solutions that cater to various residential and commercial needs. These models are designed to provide efficient, reliable, and aesthetically pleasing heating options.

One of the key features across these models is their advanced heating technology. They utilize cutting-edge infrared heating systems that ensure consistent and effective warmth. This technology not only heats up spaces quickly but also provides energy savings compared to traditional heating methods. Additionally, many models are equipped with programmable thermostats allowing users to set their desired temperature and schedule, enhancing convenience and energy efficiency.

Another hallmark of these models is their versatility in installation. The options for both vent-free and vented designs provide flexibility for various environments. Users can choose vented models for additional safety and air quality control, or opt for vent-free units that are easier to install in areas without existing ventilation systems. The range of configurations helps accommodate different space sizes and heating requirements.

In terms of design, the Desa heating solutions are crafted with aesthetics in mind. Many models feature sleek exteriors and elegant finishes, making them suitable for integration into modern or traditional interior designs. This commitment to design ensures that users do not have to sacrifice style for functionality.

Durability and reliability are emphasized throughout the line. Constructed with high-quality materials, these models are built to withstand the test of time and can function effectively under varying environmental conditions. Users can have peace of mind with warranties and support from the manufacturer.

Safety is another crucial aspect of these heating solutions. Each model is designed with safety features like automatic shut-off systems, making them safe for family use even in occupied living spaces.

In summary, the Desa VRL and CSG series offers a broad selection of heating solutions characterized by advanced infrared technology, versatile installation options, stylish designs, and robust safety measures. Whether for residential or commercial purposes, these models are engineered to meet diverse heating needs efficiently and reliably.