LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

N

N

D

E V

B L

C

Fixed

 

V

Closed

 

 

 

Openable

 

F V

Openable

B

Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum]

B= clearance to window or door that may be opened

[12 inches (305mm) minimum]

C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum]

E= clearance to unventilated soffit [12 inches (305mm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (914mm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (1829mm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (1829mm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum]

M= clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (610mm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

A

 

 

 

A = 6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B B = 6" (152mm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (305mm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

C = Maximum depth of 48" (1219mm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)

Figure 7 - Minimum Clearances for Termination Cap

For..com

108661-01D

Page 6
Image 6
Desa (V)T32N, (V)T36N SERIES, CTDV36NR installation manual Location of Termination CAP, Balcony with Perpendicular Side Wall

(V)T32N, CTDV36NR, (V)T36N SERIES specifications

The Desa CTDV36NR,(V)T36N and (V)T32N series represent an advanced line of heating appliances designed for efficient and effective home heating. These gas-fired units provide the perfect blend of functionality, aesthetics, and modern technology to meet diverse consumer needs. Renowned for their remarkable durability and compatibility with various home styles, the Desa series is an ideal choice for homeowners seeking reliable heating solutions.

One of the standout features of the Desa CTDV36NR is its ability to deliver radiant heat from a realistic flame, creating a cozy atmosphere in any room. The heating capacity is sufficient for a range of room sizes, ensuring that every corner is warmed efficiently. The units are also equipped with an easy-to-use remote control system, allowing users to adjust settings from a distance for maximum convenience.

The (V)T36N and (V)T32N models feature advanced safety technologies, including automatic shut-off systems and oxygen depletion sensors. These safety features provide peace of mind by ensuring secure operation even in confined spaces. Additionally, the series includes a battery backup option, maintaining functionality during power outages, which enhances its reliability.

Another significant characteristic of the Desa series is its aesthetic versatility. Both models come in various finishes and styles, allowing them to seamlessly integrate into existing interior designs. The high-quality glass front offers a beautiful view of the flames, enhancing ambiance while providing essential warmth.

Efficiency is a key focus in the design of the Desa CTDV series, as they are engineered to optimize fuel usage and reduce utility costs. Many models are equipped with high-efficiency gas burners that result in lower emissions and a reduced carbon footprint, making them an eco-friendlier option for heating.

Easy installation is yet another advantage of the Desa CTDV36NR, (V)T36N, and (V)T32N models. They can be vented through multiple configurations, accommodating a wide range of home layouts. Homeowners appreciate the straightforward installation process, which minimizes disruption and helps them enjoy their new heating system sooner.

In summary, the Desa CTDV36NR, (V)T36N, and (V)T32N series combine cutting-edge technology, safety features, aesthetic appeal, and energy efficiency. These heating solutions exemplify modern design principles while fulfilling the essential function of providing warmth, making them an excellent choice for any home.