Desa CHDV32NR Cleaning and Maintenance, Glass Door, pilot and burners, logs, Venting system

Models: (V)T36P SERIES CHDV32NR (V)T32P

1 36
Download 36 pages 56.57 Kb
Page 26
Image 26
Cleaning and

Cleaning and

Maintenance

GLASS DOOR WARNING: Turn off fireplace and let cool before cleaning.

pilot and burnersCAUTION:You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

logs WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not op- erate fireplace with the glass door removed, cracked, or broken.

Venting system WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint cur- ing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circum- stances present. Refer to Removing/Replacing Glass Door, page 20, when removing glass door for cleaning.

Manual background WARNING: Only parts supplied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 30). This glass door panel is a complete unit. No substitute materials may be used.

Manual background CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 20). Vacuum all glass pieces with a shop vac.

Manual background CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 30 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 20, for instructions for replacing glass door.

Manual background WARNING: Do not operate fireplace with the glass door removed, cracked, or broken.

pilot and burners

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

logs

If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 21, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 30.

Replace ember material periodically as needed. See Replacement Parts on page 30.

Venting system

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.