20

FIREPLACE INSTALLATION

Checking Gas Connections

FIREPLACE INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fire- place, or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorro- sive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect fireplace and equipment shutoff valve to gas sup- ply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fire- place, or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, page 25). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 25).

Equipment

Open

Shutoff

 

Valve

 

 

Closed

Figure 33 - Equipment Shutoff Valve

 

Equipment

Propane/LP

Shutoff

Valve

Supply Tank

 

 

Gas Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

For..com

111253-01E

Page 20
Image 20
Desa VV36EPC1 installation manual Checking GAS Connections, Pressure Testing Gas Supply Piping System

VV36EPC1 specifications

Desa VV36EPC1 is a state-of-the-art compact village generator known for its robust performance and reliability in various applications. As a versatile energy solution, it is particularly well-suited for remote areas, outdoor events, and emergency backup systems.

One of the main features of the VV36EPC1 is its superior power output, providing up to 36 kVA, making it capable of handling significant electrical loads. This generator is equipped with a powerful diesel engine that ensures efficient fuel consumption while delivering consistent power generation. The engine is designed to operate quietly, minimizing noise pollution, which is essential for residential or community use.

The VV36EPC1 incorporates advanced technology for energy management and safety. The digital control panel presents real-time data on voltage, frequency, and operating hours, allowing users to monitor performance easily. Additionally, it features an automatic voltage regulator (AVR) that stabilizes voltage output, preventing equipment damage caused by fluctuations.

Another standout characteristic of the VV36EPC1 is its rugged build quality. Constructed with durable materials, this generator is designed to withstand harsh environmental conditions. Its weather-resistant enclosure protects internal components from rain and dust, ensuring longevity and reliability during operation.

Portability is also a significant advantage of the VV36EPC1. It includes built-in wheels and a convenient lifting handle, making it easy to transport across various terrains. This feature makes it an excellent choice for construction sites, catering, or festivals, where mobility is essential.

In terms of safety, the VV36EPC1 offers multiple safeguards, including low oil shutdown and overload protection. These features ensure the generator operates safely, automatically shutting down when oil levels are low or if the load exceeds its capacity.

In summary, the Desa VV36EPC1 is a powerful, reliable, and portable generator, equipped with advanced monitoring technology and essential safety features. Whether for recreational purposes or critical power supply needs, the VV36EPC1 stands out as an optimal choice for diverse applications, providing peace of mind with its dependable performance and durability.