SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES

3

SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

5.

This fireplace reaches high temperatures. Keep children and

 

adults away from hot surfaces to avoid burns or clothing igni-

 

tion. Fireplace will remain hot for a time after shutdown. Al-

 

low surfaces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with fireplace.

7.

Do not modify this fireplace under any circumstances. Any

 

parts removed for servicing must be replaced prior to operat-

 

ing fireplace.

8.

Turn fireplace off and let cool before servicing, installing, or

 

repairing. Only a qualified service person should install, ser-

 

vice, or repair this fireplace. Have fireplace inspected annu-

 

ally by a qualified service person.

9.

You must keep control compartments, burners, and circulat-

 

ing air passages clean. More frequent cleaning may be needed

 

due to excessive lint and dust from carpeting, bedding mate-

 

rial, etc. Turn off the gas valve and pilot light before cleaning

 

fireplace.

10.

Have venting system inspected annually by a qualified service

 

person. If needed, have venting system cleaned or repaired.

 

See Cleaning and Maintenance, page 29.

11.

Keep the area around your fireplace clear of combustible ma-

 

terials, gasoline, and other flammable vapor and liquids. Do

 

not run fireplace where these are used or stored. Do not place

Upper Louver

Panel

Nailing

Flange

Glass

Door

Assembly

Piezo

Ignitor

Control

Valve

Lower

Louver Glowing

Panel Embers

Flue Collar

Log

Set

Lava

Rock

Grate

Assembly

 

items such as clothing or decorations on or around fireplace.

12.

Do not use this fireplace to cook food or burn paper or other

 

objects.

13.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this fireplace. Use only the gas type indicated on fireplace

 

nameplate.

14.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local codes,

 

with the National Electrical Code, ANSI/NFPA 70, or the Ca-

 

nadian Electrical Code, CSA C22.1.

15.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service person to arrange

 

for replacement of the unit.

16.

Do not operate fireplace if any log is broken.

17.

Do not use a blower insert, heat exchanger insert, or other ac-

 

cessory not approved for use with this fireplace.

18.

Do not operate fireplace with glass door removed, cracked, or

 

broken.

19.

Provide adequate clearances around air openings.

ON/OFF/REMOTE Switch

Blower Switch

(BKT Standard with

(Optional Installation)

CHDV Models)

 

Figure 1 - Direct-Vent Fireplace with Millivolt Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

For morevisit www..com

111906-01A

Page 3
Image 3
Desa (V)V42NA(1) installation manual Safety Information Product Identification, Local Codes

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.