For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING FIREPLACE

FOR YOUR SAFETY READ

BEFORE LIGHTING

FOR YOUR SAFETY READWARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Disconnect the wire that runs from TH to TPTH from the control valve.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and turn clockwise LIGHTING to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not re- quire accessing for lighting.

8.Turn gas control knob counterclockwise TO TURN OFF GAS to “PILOT”.

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Reconnect the wire that runs from TH to TPTH to the control valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclockwise MANUAL LIGHTING to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

 

Gas Control

Variable Control Knob

 

 

 

Knob

 

Piezo

 

 

Ignitor

ILOT

IH

O

O

 

P

 

F

N

 

F

 

 

 

 

LO

Figure 52 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise Manual background to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1. Turn gas control knob clockwise Manual background to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 23.)

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door,

page 23).

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background