FIREPLACE INSTALLATION

Check Gas Type Installing Optional Blower Accessories

17

FIREPLACE INSTALLATION

.CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type.

INSTALLING OPTIONAL BLOWER

ACCESSORIES

NOTICE:The CHDV42NRA model fireplace comes with the BKT Blower already installed as standard equip- ment. If you have a CHDV42NRA model fireplace, proceed to Installing Gas Piping to Fireplace Loca- tions, page 19.

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).

2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25). Tighten screws securely.

Blower

Location

Lower Firebox

Cavity

Side View

Magnetic Strips

Spade Terminals

Exhaust

 

Port

Green

Ground Wire Screw

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 1.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

Switch

Speed Control

Bracket

Blower

 

 

Plug-In

Control

Knob

Locknut

Control

Duplex Outlet

 

Shaft

 

(Located underneath

 

 

 

 

firebox floor against

 

 

lower right outside wall)

Figure 26 - Attaching Speed Control to Firebox

Figure 25 - Blower Model BK

For morevisit www..com

111906-01A

Page 17
Image 17
Desa (V)V42NA(1) Fireplace Installation, Check GAS Type, Installing Optional Blower Accessories, Model BK Installation

(V)V42NA(1) specifications

Desa (V)V42NA(1) is a sophisticated model designed for a wide range of applications, showcasing advanced features and cutting-edge technologies that make it stand out in its category. This model is particularly noted for its efficiency and robustness, catering to both commercial and residential needs.

One of the primary features of the Desa (V)V42NA(1) is its enhanced energy efficiency. It is engineered to optimize fuel consumption while delivering superior performance. This efficiency is primarily achieved through the use of innovative combustion technology that ensures a cleaner and more controlled burn, resulting in lower emissions. This environmental consideration makes it a suitable choice for eco-conscious consumers, aligning with global trends towards sustainability.

The Desa (V)V42NA(1) is equipped with a user-friendly interface, which allows for easy operation and control. Its digital display provides real-time information on performance parameters, making it easy for users to monitor and adjust settings as needed. This aspect of the design emphasizes user convenience and accessibility.

Another key characteristic is its adaptability. The model can easily be integrated into various settings, whether as a stand-alone unit or as part of a larger system. It is compatible with various heating and cooling technologies, making it versatile for both new installations and retrofitting projects. This flexibility is further enhanced by the availability of optional accessories that allow users to customize the unit according to their specific requirements.

Durability is another standout feature of the Desa (V)V42NA(1). Built with high-quality materials, this model is designed to withstand the rigors of everyday use while requiring minimal maintenance. This reliability ensures longevity, making it a cost-effective choice for users looking for a long-term heating solution.

In summary, the Desa (V)V42NA(1) exemplifies a harmonious blend of efficiency, user-friendliness, versatility, and durability. Its advanced technologies and features cater to a wide variety of needs, establishing it as a standout product in the heating technology market. As consumers continue to seek efficient and reliable solutions, the Desa (V)V42NA(1) stands ready to meet these growing demands.