troubleshooting
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning sup- plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM POSSIBLE CAUSE | REMEDY |
Log Set produces a clicking/ ticking noise just after burner is lit or shut off
1.Metal expanding while heat- ing or contracting while cooling
1.This is normal with most log sets. If noise is excessive, contact qualified service person
Log Set produces unwanted odors
1.Log Set burning vapors from paint, hair spray, glues, cleaners, chemi- cals, new carpet, etc. (See
IMPORTANT statement above)
2.Gas leak. See Warning statement at top of page
1.Open flue to maximum. Stop using odor causing products while log set is running
2.Locate and correct all leaks
(see Checking Gas Con- nections, page 8)
Gas odor even when control knob is in OFF position
1.Gas leak. See Warning statement at top of page
2.Control valve defective
1.Locate and correct all leaks
(see Checking Gas Con- nections, page 8)
2.Replace control valve
Gas odor during combustion 1. Gas leak. See Warning statement at top of page
1.Locate and correct all leaks
(see Checking Gas Con- nections, page 8)
18 | www.desatech.com |