troubleshooting
Continued
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
| |
When ignitor button is pressed, | 1. Gas supply turned off or | 1. | Turn on gas supply or open | |
there is spark at pilot but no |
| equipment shutoff valve |
| equipment shutoff valve |
ignition |
| closed |
|
|
| 2. | Control knob not in PILOT | 2. | Turn control knob to PILOT |
|
| position |
| position |
| 3. | Control knob not pressed | 3. | Press in control knob while |
|
| in while in PILOT position |
| in PILOT position |
| 4. | Air in gas lines when in- | 4. | Continue holding down |
|
| stalled |
| control knob. Repeat ignit- |
|
|
|
| ing operation until air is |
|
|
|
| removed |
| 5. | Pilot adjustment screw | 5. | Adjust pilot flame for ap- |
|
| closed |
| proximately 2" blue flame |
| 6. | Pilot is clogged | 6. | Clean pilot (see Cleaning |
|
|
|
| and Maintenance, page 15) |
|
|
|
| or replace pilot assembly |
| 7. | Low gas pressure | 7. | Replace gas control |
|
|
|
| |
Pilot lights but flame goes out | 1. Control knob not fully | 1. | Press in control knob fully | |
when control knob is released |
| pressed in |
|
|
2. Control knob not pressed | 2. | After pilot lights, keep con- | ||
|
| in long enough |
| trol knob pressed in 30 |
|
|
|
| seconds |
| 3. | Equipment shutoff valve | 3. | Fully open equipment shut- |
|
| not fully open |
| off valve |
| 4. | Pilot flame not touching | 4. | A) Contact local natural gas |
|
| thermocouple, which al- |
| company |
|
| lows thermocouple to cool, |
|
|
|
| causing pilot flame to go |
| B) Clean pilot (see Cleaning |
|
| out. This problem could |
| and Maintenance, page 15) |
|
| be caused by one or both |
| or replace pilot assembly |
|
| of the following: |
|
|
|
| A) Low gas pressure |
|
|
|
| B) Dirty or partially clogged |
|
|
|
| pilot |
|
|
| 5. | Thermocouple connection | 5. | Hand tighten until snug, |
|
| loose at control valve |
| then tighten 1/4 turn more |
| 6. | Thermocouple damaged | 6. | Replace thermocouple |
| 7. | Control valve damaged | 7. | Replace control valve |
|
|
|
| |
Burner does not light after pilot | 1. Burner orifice clogged | 1. | Clean burner orifice | |
is lit | 2. Inlet gas pressure is too | 2. | Contact local natural or | |
|
| low |
| propane/LP gas company |
| 3. | Thermocouple leads dis- | 3. | Reconnect leads |
|
| connected or improperly |
|
|
|
| connected |
|
|
|
|
|
| |
Delayed ignition burner | 1. Pilot flame needs adjusting | 1. | Adjust pilot flame for ap- | |
|
|
| proximately 2" blue flame | |
| 2. | Wrong pilot orifice | 2. | Replace pilot orifice set |