Desa VYGF33NRA Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Models: FPVF33NR VYGF33NRA VYGF33PRA

1 40
Download 40 pages 21.37 Kb
Page 18
Image 18

18

OPERATING FIREPLACE

For Your Safety Read Before Lighting

 

Lighting Instructions

 

 

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in OFF position.

WARNING: Burner will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 38).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 19.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burner.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

 

IH

 

 

 

 

 

O

 

 

 

F

AUTO

N

 

F

O

TOL

P

OFF

LO

 

 

I

 

 

 

 

ON

Flame Adjustment

Control Knob

Selector Switch

Knob

 

 

 

 

 

Figure 38 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

For..com

105270

Page 18
Image 18
Desa VYGF33NRA, VYGF33PRA, FPVF33NR Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

FPVF33NR, VYGF33NRA, VYGF33PRA specifications

Desa VYGF33PRA, VYGF33NRA, and FPVF33NR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. These models stand out due to their advanced features, modern technologies, and reliable characteristics.

The VYGF33PRA and VYGF33NRA variants are characterized by their versatile design, allowing them to seamlessly fit into a variety of settings. They are equipped with high-efficiency heating elements that ensure optimal heat distribution. These models utilize advanced heat exchanger technology, which not only improves efficiency but also minimizes energy consumption. This makes them an eco-friendly choice for those looking to reduce their carbon footprint without sacrificing comfort.

Safety is a top priority with these models, featuring built-in safety mechanisms like overheat protection, tip-over switches, and thermal cut-off features. This ensures that users have peace of mind while operating the units, particularly in child- or pet-friendly environments. Additionally, the user-friendly interface, complete with intuitive controls, allows for easy setting adjustments and temperature monitoring.

The FPVF33NR model also showcases remarkable features that appeal to modern consumers. It incorporates advanced digital technology, allowing for programmable settings and remote control capabilities. Users can easily adjust heating schedules, enhancing convenience and efficiency.

The energy efficiency rating is another highlight of these models. With features like smart thermostats and energy-saving modes, they are designed to minimize energy usage without compromising on performance. This not only helps in reducing utility bills but also aligns with sustainable living practices.

Moreover, these heaters are built to last, featuring durable materials that ensure longevity and reliability. The aesthetic design is appealing, allowing them to complement any interior décor effortlessly.

In conclusion, Desa VYGF33PRA, VYGF33NRA, and FPVF33NR deliver superior heating performance, user-friendly technology, and thoughtful safety features. Their combination of efficiency, durability, and modern design makes them an excellent choice for anyone in need of dependable heating solutions. Investing in these models will not only enhance comfort but also contribute to a more sustainable energy future.