INSTALLATION

Conventional Fireplace Installation (Cont.)

9

INSTALLATION

Continued

sory for models VYGF33NRA or VYGF33PRA can only be paired with the corner hearth base. If mounting fireplace and cabinet or corner mantel to the floor, an optional G3005 Series Slim Base kit may be installed.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instructions are included with each accessory.

2.When installing blower, install a properly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 9).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

4.Place hearth base accessory against wall at installation loca- tion. Cut an access hole in hearth top to run flexible gas line to fireplace (see Figure 9). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

5.Route flexible gas line through access hole in hearth base.

6.Center cabinet mantel on hearth base (see Figure 10). Make sure mantel is flush against wall.

7.Break off nailing flanges (see Figure 11) with hammer or pliers.

8.Place cardboard or other protective material on top of hearth base. Carefully set fireplace on protective material, with back of fireplace inside mantel opening.

9.Attach flexible gas line from fireplace gas regulator to gas sup- ply. See Connecting Fireplace to Gas Supply, page 13.

10.If blower is installed, route blower electrical cord through ac- cess holes in either side of fireplace. Note: Bushing may be moved if necessary. Plug electrical cord into electrical outlet.

11.Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any lami- nate trim on hearth base (laminate trim for models VYGF33PRA and VYGF33NRA only). Remove protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.

12.Check all gas connections for leaks. See Checking Gas Con- nections, page 14.

Rigid Gas Line

Electrical Outlet

 

Gas Line

 

Access

 

Hole

Hearth

Base

Figure 9 - Placing Hearth Base Accessory Against Wall

Cabinet

Mantel

Figure 10 - Installing Cabinet Mantel

Nailing

Flanges

Figure 11 - Location of Nailing Flanges

Figure 12 - Inserting Fireplace Into Cabinet Mantel

For morevisit www..com

105270

Page 9
Image 9
Desa VYGF33NRA, VYGF33PRA, FPVF33NR installation manual Placing Hearth Base Accessory Against Wall

FPVF33NR, VYGF33NRA, VYGF33PRA specifications

Desa VYGF33PRA, VYGF33NRA, and FPVF33NR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. These models stand out due to their advanced features, modern technologies, and reliable characteristics.

The VYGF33PRA and VYGF33NRA variants are characterized by their versatile design, allowing them to seamlessly fit into a variety of settings. They are equipped with high-efficiency heating elements that ensure optimal heat distribution. These models utilize advanced heat exchanger technology, which not only improves efficiency but also minimizes energy consumption. This makes them an eco-friendly choice for those looking to reduce their carbon footprint without sacrificing comfort.

Safety is a top priority with these models, featuring built-in safety mechanisms like overheat protection, tip-over switches, and thermal cut-off features. This ensures that users have peace of mind while operating the units, particularly in child- or pet-friendly environments. Additionally, the user-friendly interface, complete with intuitive controls, allows for easy setting adjustments and temperature monitoring.

The FPVF33NR model also showcases remarkable features that appeal to modern consumers. It incorporates advanced digital technology, allowing for programmable settings and remote control capabilities. Users can easily adjust heating schedules, enhancing convenience and efficiency.

The energy efficiency rating is another highlight of these models. With features like smart thermostats and energy-saving modes, they are designed to minimize energy usage without compromising on performance. This not only helps in reducing utility bills but also aligns with sustainable living practices.

Moreover, these heaters are built to last, featuring durable materials that ensure longevity and reliability. The aesthetic design is appealing, allowing them to complement any interior décor effortlessly.

In conclusion, Desa VYGF33PRA, VYGF33NRA, and FPVF33NR deliver superior heating performance, user-friendly technology, and thoughtful safety features. Their combination of efficiency, durability, and modern design makes them an excellent choice for anyone in need of dependable heating solutions. Investing in these models will not only enhance comfort but also contribute to a more sustainable energy future.