Operation

Continued

Manual Control Infrared

Models only

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW or HIGH locked positions for double burner heater or ON position for single burner heater. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Slightly press in control knob and turn counter-

clockwise to the LOW or HIGH positions for double burner heater or ON position for single burner heater.

IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

Control

Double

Control

Single

Knobs

Burners

Knob

Burner

 

 

OFF

 

 

 

PILOT

 

 

 

IGN

 

 

 

ON

 

 

 

OFF

 

Figure 20 - Burner Patterns

Inspecting Burner

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pat- tern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 22

turn heater off (see To Turn Off Gas to Ap- pliance, page 14)

see Cleaning, page 17

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Figure 21 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 22 - Incorrect Pilot Flame Pattern