Desa GWP20 GWN20T, WMP20, GP30 GN30T Troubleshooting, Observed Problem Possible Cause

Models: GWP20 GWN20T GN30 WMP20 GWP30T WMN20 GWP20T GWN30T GP30 GN30T GP30T GWN20

1 28
Download 28 pages 21.06 Kb
Page 17
Image 17

TROUBLESHOOTING

17

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.

Ignitor electrode positioned wrong

1.

Replace pilot assembly

2.

Ignitor electrode broken

2.

Replace pilot assembly

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

tor cable

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

metal or tubing. Keep ignitor cable dry

5.

Broken ignitor cable

5.

Replace ignitor cable

6.

Bad piezo ignitor

6.

Replace piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP gas only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Re- peat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 16) or replace ODS/ pilot assembly

7.Replace gas regulator

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Safety interlock system has been triggered

4.Equipment shutoff valve not fully open

5.Thermocouple connection loose at con- trol valve

6.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

7.Thermocouple damaged

8.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open equipment shutoff valve

5.Hand tighten until snug, then tighten 1/4 turn more

6.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 16) or replace ODS/ pilot assembly

7.Replace pilot assembly

8.Replace control valve

For more information, visit www.desatech.com

107884

Page 17
Image 17
Desa GWP20 GWN20T, WMP20, GP30 GN30T, GWP20T GWN30T, GWP30T WMN20 Troubleshooting, Observed Problem Possible Cause