Message

 

 

Action

 

 

 

 

DASD 1 Over Temperature (level-critical;

1.

Ensure system is being properly cooled; see “Temperature

sensor for DASD1 reported temperature

 

 

checkout” on page 26.

over recommended range)

 

 

 

 

 

 

 

Power Supply "X" Temperature Fault

1.

Ensure system is being properly cooled; see “Temperature

(level-critical; power supply "x" had over

 

 

checkout” on page 26.

temperature condition)

2.

Replace Power Supply "X"

 

 

 

 

 

 

System board is over recommended

1.

Ensure system is being properly cooled; see “Temperature

temperature (level-warning; system board

 

 

checkout” on page 26.

is over recommended temperature)

2.

Replace system board

 

 

 

 

 

 

System board is under recommended

1.

Ambient temperature must be within normal operating

temperature (level-warning; system board

 

 

specifications; see “Features and specifications” on page 4.

is under recommended temperature)

 

 

 

 

 

 

 

System overtemperatureforCPU"X"

1.

Ensure system is being properly cooled; see “Temperature

(level-warning; CPU "X" reporting over

 

 

checkout” on page 26.

temperature condition)

 

 

 

 

 

 

 

System under recommended CPU "X"

1.

Ambient temperature must be within normal operating

temperature (level-warning; system

 

 

specifications; see “Features and specifications” on page 4.

reporting under temperature condition for

 

 

 

CPU "X")

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan error messages

 

 

 

 

 

 

 

 

 

Message

 

 

Action

 

 

 

 

 

Fan "X" failure

(level-critical; fan "X"

 

1.

Check connections to fan "X"

had a failure)

 

 

2.

Replace fan "X"

 

 

 

 

 

 

 

 

Fan "X" fault

(level-critical; fan "X"

 

1.

Check connections to fan "X"

beyond recommended RPM range)

 

2.

Replace fan "X"

 

 

 

 

 

 

 

Fan "X" Outside Recommended Speed

 

1.

Replace Fan "X"

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

System shutdown

 

 

 

Refer to the following tables when experiencing system shutdown related to voltage or temperature problems.

Voltage related system shutdown

 

Message

 

Action

 

 

 

System shutoff due to "X" current over

1.

See “Power checkout” on page 24.

max value

(level-critical; system

 

 

drawing too much current on voltage "X"

 

 

bus)

 

 

 

 

 

 

System shutoff due to "X" current under

1.

See “Power checkout” on page 24.

min. value

(level-critical;

 

 

current on voltage bus "X" under minimum

 

 

value)

 

 

 

 

 

 

96 Hardware Maintenance Manual: xSeries 330

 

 

Page 104