IBM xSeries 330 manual Diagnostic error codes, 000The test passed

Models: xSeries 330

1 158
Download 158 pages 3.7 Kb
Page 95
Image 95
Diagnostic error codes

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are:

000The test passed.

195The Esc key was pressed to abort the test.

197This is a warning error and may not indicate a hardware failure. For all error codes, replace/follow the FRU/Action indicated.

Error Code/Symptom

 

FRU/Action

 

 

 

 

001-XXX-000

(Failed core tests)

1.

System Board

 

 

 

 

001-XXX-001

(Failed core tests)

1.

System Board

 

 

 

 

001-250-000

(Failed System Board

1.

System Board

ECC)

 

 

 

 

 

 

 

001-250-001

(Failed Processor

1.

System Board

Board ECC)

 

 

 

 

 

 

 

005-XXX-000

(Failed Video test)

1.

Video adapter (if installed)

 

 

2.

System Board

 

 

 

 

011-XXX-000

(Failed COM1 Serial

1.

Check loopback plug connected to externalized serial port

Port test)

 

2.

Check cable from externalized port to system board. Should connect

 

 

 

 

 

to Serial Port A on the system board (J52).

 

 

3.

System Board

 

 

 

 

011-XXX-001

(Failed COM2

1.

Check loopback plug connected to externalized serial port

Serial Port test)

 

2.

Check cable from externalized port to system board. Should connect

 

 

 

 

 

to Serial Port B on the system board (J51).

 

 

3.

System Board

 

 

 

 

014-XXX-000

(Failed Parallel Port

1.

System Board

test)

 

 

 

 

 

 

015-XXX-001(USB interface not found,

1.

System Board

board damaged)

 

 

 

 

 

 

015-XXX-198(USB device connected during

1.

Remove USB devices from USB1 and USB2.

USB test)

 

2.

System Board

 

 

 

 

 

 

020-XXX-000

(Failed PCI Interface

1.

System Board

test)

 

 

 

 

 

 

 

030-XXX-000

(Failed Internal SCSI

1.

System Board

interface test)

 

 

 

 

 

 

 

035-XXX-099

 

1.

No RAID adapters were found.

 

 

2.

If adapter is installed re-check connection.

 

 

 

 

035-XXX-S99

(Failed RAID test on PCI

1.

RAID Adapter

slot S, check System Error Log before

2.

SCSI Backplane

replacing a FRU)

 

 

3.

Cable

 

 

 

 

 

 

035-XXX-SNN

(Check System Error Log

1.

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.

before replacing a FRU, NN = SCSI ID of

 

 

failing fixed disk)

 

 

 

 

 

 

 

Chapter 7. Symptom-to-FRU index 87