Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are:

000The test passed.

195The Esc key was pressed to abort the test.

197This is a warning error and may not indicate a hardware failure. For all error codes, replace/follow the FRU/Action indicated.

Error Code/Symptom

 

FRU/Action

 

 

 

 

001-XXX-000

(Failed core tests)

1.

System Board

 

 

 

 

001-XXX-001

(Failed core tests)

1.

System Board

 

 

 

 

001-250-000

(Failed System Board

1.

System Board

ECC)

 

 

 

 

 

 

 

001-250-001

(Failed Processor

1.

System Board

Board ECC)

 

 

 

 

 

 

 

005-XXX-000

(Failed Video test)

1.

Video adapter (if installed)

 

 

2.

System Board

 

 

 

 

011-XXX-000

(Failed COM1 Serial

1.

Check loopback plug connected to externalized serial port

Port test)

 

2.

Check cable from externalized port to system board. Should connect

 

 

 

 

 

to Serial Port A on the system board (J52).

 

 

3.

System Board

 

 

 

 

011-XXX-001

(Failed COM2

1.

Check loopback plug connected to externalized serial port

Serial Port test)

 

2.

Check cable from externalized port to system board. Should connect

 

 

 

 

 

to Serial Port B on the system board (J51).

 

 

3.

System Board

 

 

 

 

014-XXX-000

(Failed Parallel Port

1.

System Board

test)

 

 

 

 

 

 

015-XXX-001(USB interface not found,

1.

System Board

board damaged)

 

 

 

 

 

 

015-XXX-198(USB device connected during

1.

Remove USB devices from USB1 and USB2.

USB test)

 

2.

System Board

 

 

 

 

 

 

020-XXX-000

(Failed PCI Interface

1.

System Board

test)

 

 

 

 

 

 

 

030-XXX-000

(Failed Internal SCSI

1.

System Board

interface test)

 

 

 

 

 

 

 

035-XXX-099

 

1.

No RAID adapters were found.

 

 

2.

If adapter is installed re-check connection.

 

 

 

 

035-XXX-S99

(Failed RAID test on PCI

1.

RAID Adapter

slot S, check System Error Log before

2.

SCSI Backplane

replacing a FRU)

 

 

3.

Cable

 

 

 

 

 

 

035-XXX-SNN

(Check System Error Log

1.

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.

before replacing a FRU, NN = SCSI ID of

 

 

failing fixed disk)

 

 

 

 

 

 

 

Chapter 7. Symptom-to-FRU index 87

Page 95
Image 95
IBM xSeries 330 manual Diagnostic error codes

xSeries 330 specifications

The IBM xSeries 330 is a versatile and reliable server designed to meet the demands of small to medium-sized businesses and enterprise environments. This server model, part of IBM’s xSeries line, is known for its solid performance, expandability, and robust features.

One of the main highlights of the xSeries 330 is its scalability. The server supports multiple configurations, with options for single or dual Intel Pentium III processors, allowing it to handle various workloads efficiently. It can accommodate up to 8GB of RAM, which is essential for running memory-intensive applications smoothly. This capacity ensures that businesses can upgrade their systems rather than replace them, providing a cost-effective solution for managing growing data needs.

In terms of storage, the xSeries 330 offers flexible options with up to six hot-swap hard drives. This feature enhances the server's uptime, as drives can be replaced without shutting down the system. The server supports RAID configurations, including RAID 0, 1, and 5, enhancing data protection and performance.

Connectivity is another critical aspect of the xSeries 330. It comes equipped with multiple PCI slots, allowing for the addition of various expansion cards to improve functionality, such as network controllers, graphics cards, and storage controllers. The server also provides integrated network management tools, which enable efficient monitoring and comprehensive troubleshooting, reducing downtime and maintenance efforts.

The xSeries 330 is supported by IBM's advanced management technologies, including the IBM Director. This software simplifies remote management, enabling IT personnel to monitor system health, perform updates, and automate tasks without the need to be physically present at the server location. Additionally, the server includes features like Automatic Server Restart and Predictive Failure Analysis, which help to predict and prevent potential hardware failures.

The design of the xSeries 330 emphasizes ease of use, with tool-less access to components, making upgrades and maintenance straightforward. Its compact form factor ensures that it can fit into diverse server environments, from traditional server rooms to modern data centers.

In summary, the IBM xSeries 330 stands out for its powerful performance, scalability, and management capabilities. These features make it a valuable asset for businesses looking to enhance their operational efficiency and prepare for future growth. With its reliability and versatile architecture, the xSeries 330 continues to be a respected choice among IT professionals.