Perle Systems SCS, STS manual Snmp Traps, Error Codes

Models: SCS STS

1 408
Download 408 pages 44.1 Kb
Page 279
Image 279

 

 

 

I/O SNMP Traps

 

 

 

 

 

 

Error Codes

 

 

 

 

 

 

 

 

 

Code

Name

Description

 

 

 

 

 

 

01

Illegal Function

The function code received in the query is not an allowable action for

 

 

 

 

the server (or slave).

 

02

Illegal Data

The data address received in the query is not an allowable address for

 

 

 

Address

the server (or slave).

 

03

Illegal Data Value

A value contained in the query data field is not an allowable value for

 

 

 

 

server (or slave).

 

04

Slave Device

An unrecoverable error occurred while the server (or slave) was

 

 

 

Failure

attempting to perform the requested action.

 

 

 

 

 

 

I/O SNMP Traps

When you enable SNMP traps for Digital and Analog inputs, a value is returned when an alarm triggers or clears. This section decodes the SNMP specific trap numbers. The value returned from the trap will be the I/O channel number that is generating the trap.

Specific

 

 

Trap #

Alarm

Description

 

 

 

0

IO_DI_ALARM_SENSOR

Trap for the Digital input Trigger.

 

 

 

1

IO_DI_ALARM_SERIAL_DSR

Trap for the Digital input DSR serial pin Trigger.

 

 

 

2

IO_DI_ALARM_SERIAL_DCD

Trap for the Digital input DCD serial pin Trigger.

 

 

 

3

IO_DI_ALARM_SERIAL_CTS

Trap for the Digital input CTS serial pin Trigger.

 

 

 

4

IO_AI_ALARM_LEVEL1

Trap for Analog input Alarm Level 1.

 

 

 

5

IO_AI_ALARM_LEVEL2

Trap for Analog input Alarm Level 2.

 

 

 

6

IO_AI_ALARM_LEVEL3

Trap for Analog input Alarm Level 3.

 

 

 

7

IO_AI_ALARM_LEVEL4

Trap for Analog input Alarm Level 4.

 

 

 

8

IO_AI_ALARM_LEVEL5

Trap for Analog input Alarm Level 5.

 

 

 

9

IO_DI_ALARM_SENSOR_CLEAR

Trap for Digital input trigger Clear Mode.

 

 

 

10

IO_DI_ALARM_SERIAL_DSR_CLEAR

Trap for Digital input DSR serial pin trigger Clear

 

 

Mode.

 

 

 

11

IO_DI_ALARM_SERIAL_DCD_CLEAR

Trap for Digital input DCD serial pin trigger Clear

 

 

Mode.

 

 

 

12

IO_DI_ALARM_SERIAL_CTS_CLEAR

Trap for Digital input CTS serial pin trigger Clear

 

 

Mode.

 

 

 

13

IO_AI_ALARM_LEVEL1_CLEAR

Trap for the Analog input Alarm Level 1 Clear.

 

 

 

14

IO_AI_ALARM_LEVEL2_CLEAR

Trap for the Analog input Alarm Level 2 Clear.

 

 

 

15

IO_AI_ALARM_LEVEL3_CLEAR

Trap for the Analog input Alarm Level 3 Clear.

 

 

 

16

IO_AI_ALARM_LEVEL4_CLEAR

Trap for the Analog input Alarm Level 4 Clear.

 

 

 

17

IO_AI_ALARM_LEVEL5_CLEAR

Trap for the Analog input Alarm Level 5 Clear.

 

 

 

279