Serial Port Profiles

Advanced Tab Field Descriptions

Configure the following parameters:

Routing

Determines the routing mode (RIP, Routing Information Protocol) used on the

 

PPP interface.This is the same function as the Framed-Routingattribute for

 

RADIUS authenticated users.

 

Data Options

 

z None—Disables RIP over the PPP interface.

 

z Send—Sends RIP over the PPP interface.

 

z Listen—Listens for RIP over the PPP interface.

 

z Send and Listen—Sends RIP and listens for RIP over the PPP interface.

 

Default: None

ACCM

Specifies the ACCM (Asynchronous Control Character Map) characters that

 

should be escaped from the data stream.

 

Field Format: This is entered as a 32-bit hexadecimal number with each bit

 

specifying whether or not the corresponding character should be escaped. The

 

bits are specified as the most significant bit first and are numbered 31-0. Thus

 

if bit 17 is set, the 17th character should be escaped, that is, 0x11 (XON). The

 

value 000a0000 will cause the control characters 0x11 (XON) and 0x13

 

(XOFF) to be escaped on the link, thus allowing the use of XON/XOFF

 

(software) flow control. If you have selected Soft Flow Control on the Serial

 

Port, you must enter a value of at least 000a0000 for the ACCM.

 

Default: 00000000, which means no characters will be escaped

MRU

The Maximum Receive Unit (MRU) parameter specifies the maximum size of

 

PPP packets that the IOLAN’s port will accept. If your user is authenticated by

 

the IOLAN, the MRU value will be overridden if you have set a MTU value for

 

the user. If your user is authenticated by RADIUS and the RADIUS parameter

 

Framed-MTUis set in the RADIUS file, the IOLAN will use the value in the

 

RADIUS file in preference to the value configured here.

 

Range: 64-1500 bytes

 

Default: 1500

176

IOLAN SDS/SCS/STS User’s Guide, Version 3.6

Page 176
Image 176
Perle Systems manual Iolan SDS/SCS/STS User’s Guide, Version