Serial Port Profiles

Trigger

When the trigger condition is met, triggers the specified alarm action.

 

Data Options:

 

z Disabled—No alarm settings. This is the default.

 

z Inactive—When the expected Digital input is active, going inactive will

 

trigger an alarm.

 

z Active—When the expected Digital input is inactive, going active will

 

trigger an alarm.

 

Default: Disabled

Auto Clear Mode

When enabled, automatically clears the alarm when the trigger condition

 

changes; for example, if the Trigger is Inactive and the alarm is triggered, once

 

the input becomes active again, the alarm will automatically be cleared

 

Default: Enabled

Manual Clear

When enabled, a triggered alarm must be manually cleared.

Mode

Default: Disabled

Email

When enabled, sends an email alert to an email account(s) set up in the System

 

settings when an alarm is triggered or cleared. The email alert data includes the

 

severity level and the value that caused the alarm to trigger or clear. The Email

 

Alert is associated with Level Critical.

 

Default: Disabled

Syslog

When enabled, sends a message to syslog when an alarm is triggered or

 

cleared. The syslog entry includes the severity level and the value that caused

 

the alarm to trigger or clear. The syslog message is associated with Level

 

Critical.

 

Default: Disabled

SNMP

When enabled, sends an SNMP trap when an alarm is triggered or cleared. The

 

trap consists of the severity level and whether the alarm was triggered or

 

cleared.

 

Default: Disabled

160

IOLAN SDS/SCS/STS User’s Guide, Version 3.6

Page 160
Image 160