IBM xSeries 330 manual Diagnostics panel, Light Path, Ps Mem Tempcpu Fan Vrm Sp Pci

Models: xSeries 330

1 158
Download 158 pages 3.7 Kb
Page 22
Image 22
Diagnostics panel

To view the LEDs on the system board:

1.Turn off the server and any peripheral devices.

2.Remove the cables.

3.Remove the server from the rack and place it on a flat, non-conductive surface.

4.Remove the server cover (see “Removing the cover” on page 44).

Note: Refer to “Working inside a server with power on” on page 42 for instructions and precautions for working in the server with the power on.

5.Press and hold the Light Path Diagnostics (blue) button on the diagnostics panel. The LEDs will illuminate while the switch is pressed.

Note: You can illuminate the LEDs for a maximum of two minutes. After that time, the circuit that powers the LEDs is exhausted.

Diagnostics panel

The following illustration shows the LEDs on the diagnostics panel on the system board. See Table 3 for information on identifying problems using these LEDs.

Light

Path

PS MEM

TEMP CPU

FAN VRM

SP PCI

Table 3. Light Path Diagnostics.

LED

Description

 

 

PS

Power supply error

 

 

MEM

Memory error occurred

 

 

TEMP

System temperature exceeded maximum rating

 

 

CPU

Microprocessor error

 

 

FAN

Fan failed or operating slowly

 

 

VRM

Voltage regulator module error

 

 

SP

Error occurred on SP bus

 

 

PCI

Error occurred on an adapter in PCI slot 1 or 2, or one of the PCI service

 

devices integrated on the system board.

 

 

See “Information panel system error LED” on page 85 for appropriate action.