IBM xSeries 330 manual SCSI error codes, Temperature error messages

Models: xSeries 330

1 158
Download 158 pages 3.7 Kb
Page 103
Image 103

Error Code/Symptom

 

 

 

FRU/Action

 

 

 

 

 

 

 

01298101

 

(Bad update data for

 

1.

Ensure all processors are the same stepping level and cache size.

processor 1)

 

 

 

2.

Processor 1

 

 

 

 

 

 

 

 

 

 

 

01298102

 

(Bad update data for

 

1.

Ensure all processors are the same stepping level and cache size.

processor 2)

 

 

 

2.

Processor 2

 

 

 

 

 

 

 

 

 

 

 

I9990301

 

(Fixed boot sector error)

 

1.

Hard Disk Drive

 

 

 

 

2.

Cable

 

 

 

 

3.

SCSI Backplane

 

 

 

 

4.

System Board

 

 

 

 

 

 

 

I9990305

 

(Fixed boot sector error,

 

1.

Install operating system to hard disk drive.

no operating system installed)

 

 

 

 

 

 

 

 

 

 

 

I9990650

 

(AC power has been

 

1.

Check power cable

restored)

 

 

 

2.

Check for interruption of power supply

 

 

 

 

 

 

 

 

3.

Power Cable

 

 

 

 

 

 

 

 

 

 

 

 

SCSI error codes

 

 

 

 

 

 

 

 

 

 

 

Error Code

 

 

FRU/Action

 

 

 

 

 

All SCSI Errors

One or more of

 

1.

External SCSI devices must be powered-on before you power-on

the following might be causing the problem:

 

 

the server.

• A failing SCSI device (adapter, drive,

 

2.

The cables for all external SCSI devices are connected correctly.

controller)

 

 

 

3.

If you have attached an external SCSI device to the server, make

 

 

 

 

 

• An improper SCSI configuration or SCSI

 

 

sure the external SCSI termination is set to automatic.

termination jumper setting

 

4.

The last device in each SCSI chain is terminated correctly.

 

 

 

 

 

• Duplicate SCSI IDs in the same SCSI

 

5.

The SCSI devices are configured correctly.

chain

 

 

 

 

 

 

 

 

 

 

• A missing or improperly installed SCSI

 

 

 

terminator

 

 

 

 

 

• A defective SCSI terminator

 

 

 

• An improperly installed cable

 

 

 

• A defective cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature error messages

 

 

 

 

 

 

 

 

 

Message

 

 

Action

 

 

 

DASD Over recommended Temperature

1.

Ensure system is being properly cooled; see “Temperature

(sensor X)

 

(level-warning; DASD

 

 

checkout” on page 26.

bay "X" had over temperature condition)

 

 

 

 

 

 

DASD under recommended temperature

1.

Ambient temperature must be within normal operating

(sensor X)

(level-warning; direct access

 

 

specifications; see “Features and specifications” on page 4.

storage device bay "X" had under

 

 

 

temperature condition)

 

 

 

 

 

 

 

 

 

 

Chapter 7. Symptom-to-FRU index 95

Page 103
Image 103
IBM xSeries 330 manual SCSI error codes, Temperature error messages