Error Code/Symptom |
|
|
| FRU/Action | ||
|
|
|
|
|
|
|
01298101 |
| (Bad update data for |
| 1. | Ensure all processors are the same stepping level and cache size. | |
processor 1) |
|
|
| 2. | Processor 1 | |
|
|
|
| |||
|
|
|
|
|
|
|
01298102 |
| (Bad update data for |
| 1. | Ensure all processors are the same stepping level and cache size. | |
processor 2) |
|
|
| 2. | Processor 2 | |
|
|
|
| |||
|
|
|
|
|
|
|
I9990301 |
| (Fixed boot sector error) |
| 1. | Hard Disk Drive | |
|
|
|
| 2. | Cable | |
|
|
|
| 3. | SCSI Backplane | |
|
|
|
| 4. | System Board | |
|
|
|
|
|
|
|
I9990305 |
| (Fixed boot sector error, |
| 1. | Install operating system to hard disk drive. | |
no operating system installed) |
|
|
|
| ||
|
|
|
|
|
|
|
I9990650 |
| (AC power has been |
| 1. | Check power cable | |
restored) |
|
|
| 2. | Check for interruption of power supply | |
|
|
|
| |||
|
|
|
| 3. | Power Cable | |
|
|
|
|
| ||
|
|
|
|
|
|
|
SCSI error codes |
|
|
| |||
|
|
|
|
|
| |
|
| Error Code |
|
| FRU/Action | |
|
|
|
|
| ||
All SCSI Errors | One or more of |
| 1. | External SCSI devices must be | ||
the following might be causing the problem: |
|
| the server. | |||
• A failing SCSI device (adapter, drive, |
| 2. | The cables for all external SCSI devices are connected correctly. | |||
controller) |
|
|
| 3. | If you have attached an external SCSI device to the server, make | |
|
|
|
|
| ||
• An improper SCSI configuration or SCSI |
|
| sure the external SCSI termination is set to automatic. | |||
termination jumper setting |
| 4. | The last device in each SCSI chain is terminated correctly. | |||
|
|
|
|
| ||
• Duplicate SCSI IDs in the same SCSI |
| 5. | The SCSI devices are configured correctly. | |||
chain |
|
|
|
| ||
|
|
|
|
|
| |
• A missing or improperly installed SCSI |
|
|
| |||
terminator |
|
|
|
|
| |
• A defective SCSI terminator |
|
|
| |||
• An improperly installed cable |
|
|
| |||
• A defective cable |
|
|
| |||
|
|
|
|
| ||
|
|
|
|
|
|
|
Temperature error messages |
| |||||
|
|
|
|
|
| |
|
| Message |
|
| Action | |
|
|
| ||||
DASD Over recommended Temperature | 1. | Ensure system is being properly cooled; see “Temperature | ||||
(sensor X) |
|
|
| checkout” on page 26. | ||
bay "X" had over temperature condition) |
|
|
| |||
|
|
| ||||
DASD under recommended temperature | 1. | Ambient temperature must be within normal operating | ||||
(sensor X) |
|
| specifications; see “Features and specifications” on page 4. | |||
storage device bay "X" had under |
|
|
| |||
temperature condition) |
|
|
| |||
|
|
|
|
|
|
|
Chapter 7.