IBM xSeries 330 manual Error Code/Symptom

Models: xSeries 330

1 158
Download 158 pages 3.7 Kb
Page 96
Image 96

Error Code/Symptom

 

FRU/Action

 

 

 

 

035-253-S99

(RAID adapter

1.

ServeRAID Adapter in slot S is not configured properly. Obtain

initialization failure)

 

the basic and extended configuration status and refer to the

 

 

 

ServeRAID Hardware Maintenance Manual for more information.

 

 

2.

Cable

 

 

3.

SCSI Backplane

 

 

4.

Adapter

 

 

 

 

089-XXX-001

(Failed Microprocessor

1.

Microprocessor 1

test)

 

2.

System Board

 

 

 

 

 

 

089-XXX-002

(Failed

1.

Microprocessor 2

Optional Microprocessor test)

2.

System Board

 

 

 

 

 

 

165-XXX-000

(Failed Service Processor

1.

System Board

test)

 

 

 

 

 

 

 

180-XXX-000

(Diagnostics LED failure)

1.

Run Diagnostic LED test for the failing LED.

 

 

 

 

180-XXX-001

(Failed information LED

1.

Switch Card / Information LED Panel

panel test)

 

 

 

 

 

 

 

180-XXX-003

(Failed System Board LED

1.

System Board

test)

 

 

 

 

 

 

 

180-XXX-005

(Failed SCSI

1.

SCSI Backplane

Backplane LED test)

2.

SCSI Backplane Cable

 

 

 

 

3.

System Board

 

 

 

 

201-XXX-0NN

(Failed Memory test,

1.

DIMM Location slots 1-4 where NN = DIMM location.

see "Memory Settings" on page 33)

 

Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN

 

 

 

 

 

 

4=DIMM 4

 

 

2.

System Board

 

 

 

201-XXX-999(Multiple DIMM failure, see

1.

See error text for failing DIMMs

error text)

 

2.

System Board

 

 

 

 

 

 

202-XXX-001

(Failed System Cache

1.

Microprocessor 1

test)

 

2.

System Board

 

 

 

 

 

 

202-XXX-002

(Failed System Cache test)

1.

Microprocessor 2

 

 

2.

System Board

 

 

 

 

206-XXX-000

(Failed Diskette Drive

1.

Try test with another diskette

test)

 

2.

Cable

 

 

 

 

3.

Diskette Drive

 

 

4.

System Board

 

 

 

 

215-XXX-000

(Failed IDE CD-ROM

1.

CD-ROM Drive Cables

test)

 

2.

CD-ROM Drive

 

 

 

 

3.

System Board

 

 

 

 

217-XXX-000

(Failed Fixed Disk

1.

Fixed Disk 1

test)

 

2.

System Board

Note: If RAID is configured, the fixed

 

 

disk number refers to the RAID

 

 

logical array

 

 

 

 

 

88 Hardware Maintenance Manual: xSeries 330

 

 