FRESH AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING ICONG 001WARNING

 

 

 

 

 

 

FOR

 

This heater shall not be installed in a confined space unless

 

 

 

COMBUSTION

 

provisions are provided for adequate combustion and ventilation

 

 

 

 

air. Read the following instructions to insure proper fresh air for

 

 

 

AND

 

 

 

 

 

this and other fuel-burning appliances in your home.

 

 

 

 

 

 

VENTILATION

 

 

 

 

 

 

Today’s homes are built more energy efficient than ever. New materials, increased

 

 

 

insulation, and new construction methods help reduce heat loss in homes. Home

 

 

 

 

 

owners weather strip and caulk around windows and doors to keep the cold air out

 

 

 

and the warm air in. During heating months, home owners want their homes as

 

 

 

 

 

airtight as possible.

 

 

 

 

 

 

 

 

While it is good to make your home energy efficient, your home needs to breathe.

 

 

 

 

 

Fresh air must enter your home. All fuel-burning appliances need fresh air for

 

 

 

 

 

proper combustion and ventilation.

 

 

 

 

 

 

 

 

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from

 

 

 

the house to operate. You must provide adequate fresh air for these appliances.

 

 

 

 

 

This will insure proper venting of vented fuel-burning appliances.

 

 

 

 

 

 

 

PROVIDING ADEQUATE VENTILATION

 

 

 

 

 

 

 

The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1,

 

 

 

 

Section 5.3, Air for Combustion and Ventilation.

 

 

 

 

 

 

 

All spaces in homes fall into one of the three following ventilation classifications:

 

 

 

 

1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space.

 

 

 

 

The information on pages 5 through 7 will help you classify your space and provide

 

 

adequate ventilation.

 

 

 

 

 

 

 

Unusually Tight Construction

 

 

 

 

 

 

 

The air that leaks around doors and windows may provide enough fresh air for

 

 

 

 

combustion and ventilation. However, in buildings of unusually tight construction,

 

 

you must provide additional fresh air.

 

 

 

 

 

 

 

 

Unusually tight construction is defined as construction where:

 

 

 

 

 

a. walls and ceilings exposed to the outside atmosphere have a continu-

 

 

 

 

 

ous water vapor retarder with a rating of one perm or less with open-

 

 

 

 

 

ings gasketed or sealed and

 

 

 

 

 

 

 

 

b. weather stripping has been added on openable windows and doors and

 

 

 

 

 

c. caulking or sealants are applied to areas such as joints around window

 

 

 

 

 

and door frames, between sole plates and floors, between wall-ceiling

 

 

 

 

 

joints, between wall panels, at penetrations for plumbing, electrical, and

 

 

 

 

 

gas lines, and at other openings.

 

 

 

 

 

 

 

If your home meets all of the three criteria above, you must provide addi-

 

 

 

 

tional fresh air. See Ventilation Air From Outdoors, page 8.

 

 

 

 

 

 

 

If your home does not meet all of the three criteria above, proceed to page 6.

 

 

 

Unconfined Space

 

 

 

 

 

 

 

 

The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon-

 

 

 

 

 

fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for

 

 

 

 

 

each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals

 

 

 

 

 

length x width x height of space). Include adjoining rooms only if there are

 

 

 

 

 

doorless passageways or ventilation grills between the rooms.

 

 

 

 

 

 

 

 

Confined Space

 

 

 

 

 

 

 

 

The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined

 

 

 

 

 

space as having an air volume of less than 50 cubic feet (127 cubic cm) for each

 

 

 

 

 

1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length

 

 

 

 

 

x width x height of space). Include adjoining rooms only if there are doorless

 

 

 

 

 

 

 

passageways or ventilation grills between the rooms.