)2
FAULT DIAGNOSIS
1.IGNITION : Position 1
2.Left Temperature selector wheel : HI
Right Temperature selector wheel : LO
3.Within 20 seconds press the REST and EC buttons simultaneously for more than 5 seconds.
4.The LED in the RECIRCULATE button flashes and "OFF" appears on the display.
5.Press the right AUTO button until all DTC's are displayed and recorded.
6.To erase all codes must be read out. Press both AUTO buttons simultaneously for more than 2 seconds. "d" will be displayed on the left and "FF" is displayed on the right. The erase can be canceled by pressing the AUTO button.
7.Reset temperature selector to normal setting.
8.IGNITION : OFF to end the test program.
| FAULT CODES - 140 Chassis from 9/95 |
|
|
DTC Readout | Description |
|
|
026 | CAN Bus Communication |
|
|
226 | |
|
|
227 | Outside Air Temperature Sensor (B10/5) to 1996, (B14) as of 1997 |
|
|
228 | Left Heater Core Temperature Sensor (B10/2) |
|
|
229 | Right Heater Core Temperature Sensor (B10/3) |
|
|
230 | Evaporator Temperature Sensor (B10/6) |
|
|
231 | Engine Coolant Temperature Sensor (B11/4) |
| DFI or IFI models Right Engine Coolant Temperature Sensor (B11/10) to 1996 |
|
|
232 | Refrigerant Pressure Sensor (B12) |
|
|
233 | Refrigerant Temperature Sensor (B12/1) |
|
|
234 | Sun Sensor (B32) |
|
|
235 | Emissions (Refrigerant Leak) Sensor (B31) |
|
|
241 | Refrigerant Level |
|
|
416 | Coolant Circulation Pump (A31m1) |
|
|
417 | Left Duovalve (Water Valve) (Y21y1) |
|
|
418 | Right Duovalve (Water Valve) (Y21y2) |
|
|
419 | A/C Compressor Electromagnetic Clutch (A9k1) |
|
|
420 | Closed (Idle) Throttle Speed Increase |
|
|
421 | Pulse Module (N65) |
|
|
422 | Serial Interface Connection (K1) to Instrument Cluster (IC) |
|
|
423 | Switchover Valve Block (Y11) |
|
|
424 | Activated Charcoal Filter Actuator (A32m2) : OPEN |
|
|
425 | Activated Charcoal Filter Actuator (A32m2) : CLOSE |
|
|
432 | Maximum Heat |
|
|
100