1ANALOG CODES
CS1000 Code Scanner OB15-11
DTC Readout | Possible Cause of Faults |
|
|
19 | ASR/ETS hydraulic unit, right rear axle solenoid valve(hold) |
|
|
20 | ASR/ETS hydraulic unit, right rear axle solenoid valve (release) |
|
|
21 | ASR/ETS hydraulic unit, switchover/solenoid valve |
|
|
22 | ASR/ETS hydraulic unit, inlet solenoid valve |
|
|
23 | ASR only: ASR system pressure too low |
|
|
24 | ASR/ETS hydraulic unit, |
|
|
27 | Stop lamp switch |
|
|
28 | Battery voltage too low, circuit 87 |
|
|
29 | ETS only Circuit 30, volts supply |
|
|
30 | ASR only CAN date bus to EA/CC/ISC control module, interrupted |
|
|
31 | ASR only CAN communication with |
| right |
| faulty |
|
|
32 | ASR only CAN communication with DI or left and right DI control module, faulty |
|
|
33 | ASR only CAN communication faulty in general |
|
|
34 | ETS only Brakes overheated |
|
|
35 | Model 129.076,140.04/05/07 Master brake cylinder switchover valve |
|
|
36 | Model 129.076,140.04/05/07 ASR lateral acceleration sensor, open circuit |
|
|
37 | Model 129.076,140.04/05/07 ASR lateral acceleration sensor, illogical |
|
|
38 | ETS only EST/SPS control module not identify the software (not coded) |
|
|
39 | Model 140/210 ETS/SPS or ASR/SPS control module |
|
|
40 | Model 140 SPS |
|
|
41 | Model 140/210 ASR/SPS or ETS/SPS control module |
|
|
63