647)+!2/#7)79
READING ACTUAL VALUES
1.IGNITION : Position 1
2.Set temperature selector to 72 degrees F.
3.Press the REST button for more than 6 seconds.
4.The left display will alternately show the number "01" and the
5.Press the FAN button and the next component number and its value will be displayed.
6.Press the REST button to end the test program.
COMPONENT UNDER TEST
Number | Component |
|
|
01 | |
|
|
02 | Outside Temperature Sensor (B14) |
|
|
03 | Left Heater Core Temperature Sensor (B10/2) |
|
|
05 | Evaporator Temperature Sensor (B10/6) |
|
|
06 | Engine Coolant Temperature Sensor (ECT) (B11/4) |
|
|
07 | Refrigerant Pressure in Bar |
|
|
08 | Refrigerant Temperature Sensor (B12/1) |
|
|
09 | Not Used |
|
|
10 | Blower Control Voltage |
|
|
20 | Control Current for Auxiliary Fan exp. : 7 = 7 mA |
|
|
21 | Engine RPM. example 00..99 (x100) = 9900 |
|
|
22 | Vehicle Speed |
|
|
23 | PIN 58D exp. 99.0 = 99% of Battery Voltage |
|
|
24 | Battery Voltage : 12.8 = 12,8 Volt |
|
|
40 | A/C Controller Software Version Coding |
|
|
41 | A/C Controller Hardware Version |
|
|
42 | Variant code 1 |
|
|
43 | Variant code 2 |
|
|
50 | Not Used |
|
|
51 | Not Used |
|
|
52 | Not Used |
|
|
54 | ON/OFF A/C Compressor emergency off signal from engine control module. |
|
|
90