)2
| FAULT CODES - 140 Chassis to 8/95 |
| |
|
|
|
|
DTC Readout | Description | Cause | Fault Type |
|
|
|
|
145 | Rear Evaporator Temperature Sensor (B10/11) | Short Circuit | INTERMITTENT |
|
|
|
|
146 | Rear Evaporator Temperature Sensor (B10/11) | Short or Open Circuit | CONTINUOUS |
|
|
|
|
147 | Rear Evaporator Temperature Sensor (B10/11) | Short or Open Circuit | INTERMITTENT |
|
|
|
|
148 | Coolant Circulation Pump (A31/1m1) | Short Circuit | CONTINUOUS |
|
|
|
|
149 | Coolant Circulation Pump (A31/1m1) | Short Circuit | INTERMITTENT |
|
|
|
|
150 | Coolant Circulation Pump (A31/1m1) | Short or Open Circuit | CONTINUOUS |
|
|
|
|
151 | Coolant Circulation Pump (A31/1m1) | Short or Open Circuit | INTERMITTENT |
|
|
|
|
152 | Coolant Circulation Pump (A31/1m1) | Overload | CONTINUOUS |
|
|
|
|
153 | Coolant Circulation Pump (A31/1m1) | Overload | INTERMITTENT |
|
|
|
|
156 | Left Duovalve (Water Valve) (A31/1y1) | Short Circuit | CONTINUOUS |
|
|
|
|
157 | Left Duovalve (Water Valve) (A31/1y1) | Short Circuit | INTERMITTENT |
|
|
|
|
158 | Left Duovalve (Water Valve) (A31/1y1) | Short or Open Circuit | CONTINUOUS |
|
|
|
|
159 | Left Duovalve (Water Valve) (A31/1y1) | Short or Open Circuit | INTERMITTENT |
|
|
|
|
160 | Right Duovalve (Water Valve) (A31/1y2) | Short Circuit | CONTINUOUS |
|
|
|
|
161 | Right Duovalve (Water Valve) (A31/1y2) | Short Circuit | INTERMITTENT |
|
|
|
|
162 | Right Duovalve (Water Valve) (A31/1y2) | Short or Open Circuit | CONTINUOUS |
|
|
|
|
163 | Right Duovalve (Water Valve) (A31/1y2) | Short or Open Circuit | INTERMITTENT |
|
|
|
|
164 | Rear Refrigerant | Short Circuit | CONTINUOUS |
|
|
|
|
165 | Rear Refrigerant | Short Circuit | INTERMITTENT |
|
|
|
|
166 | Rear Refrigerant | Short or Open Circuit | CONTINUOUS |
|
|
|
|
167 | Rear Refrigerant | Short or Open Circuit | INTERMITTENT |
|
|
|
|
168 | Rear Tunnel Flap Vacuum Valve (Y67/1) | Short Circuit | CONTINUOUS |
|
|
|
|
169 | Rear Tunnel Flap Vacuum Valve (Y67/1) | Short Circuit | INTERMITTENT |
|
|
|
|
170 | Rear Tunnel Flap Vacuum Valve (Y67/1) | Short or Open Circuit | CONTINUOUS |
|
|
|
|
| Rear Tunnel/#Flap Vacuum7)79Valve (Y67/1) | Short or Open Circuit | INTERMITTENT |
|
|
|
|
READING ACTUAL VALUES
1.IGNITION : Position 1
2.Press the AUTO button
3.Set both temperature selectors to 72 degrees F.
4.Press the REST button for more than 5 seconds.
5.The left display will alternately show the number "1" and the
6.Press the AUTO button and the next component number and its value will be displayed.
7.Press the REST button to end the test program.
98