Mercedes-Benz CS1000 34562, Reading Actual Values, Component Under Test, Number, Fault Diagnosis

Models: CS1000

1 169
Download 169 pages 13.08 Kb
Page 84
Image 84

￿￿3456)￿￿￿￿￿￿￿￿2￿￿￿￿￿￿￿￿￿￿￿￿￿

READING ACTUAL VALUES

1.Remove the operating console from the TAU

2.At the upper side of the operating consol there is a display.

3.Ignition ON : Position 1

4.The fan speed selector NOT on position 1

5.The display alternates between the sensor/component number and the value of that sensor/component. Example: "OP E" : Open circuit or "CL O" : Closed circuit.

COMPONENT UNDER TEST

Number

Component

 

 

02

Interior Temperature Sensor

 

 

04

Exterior Temperature Sensor

 

 

06

Evaporator Temperature Sensor

 

 

08

Left Heater Core Temperature Sensor

 

 

10

Right Heater Core Temperature Sensor

 

 

12

Engine Coolant Temperature Sensor (ECT)

 

 

14

Left Temperature Selector Wheel Setting (Degree C)

 

 

16

Right Temperature Selector Wheel Setting (Degree C)

 

 

18

Vehicle Speed Signal(km/h)

 

 

20

Soft Top OPEN : "U", Soft Top CLOSED : "O"

 

 

22

Power Supply Voltage

 

 

83

OFF/ON (Not Used)

 

 

84

Blower Motor Voltage "050" (0.5v) - "600" (6.0v)

 

 

FAULT DIAGNOSIS

1Turn temperature selector wheel into the white area.

2Place the air speed selector at position 0 and the air direction to "DOWN"

3IGNITION = ON : Position 1

4Within the next 10 sec., press the "RECIRCULATE AIR" and "REST" button simultaneously for 3 sec.

5Press the AUTO button until all error numbers are read and recorded.

84

Page 84
Image 84
Mercedes-Benz CS1000 manual 34562, Reading Actual Values, Component Under Test, Number, Fault Diagnosis