3456)2
READING ACTUAL VALUES
1.Remove the operating console from the TAU
2.At the upper side of the operating consol there is a display.
3.Ignition ON : Position 1
4.The fan speed selector NOT on position 1
5.The display alternates between the sensor/component number and the value of that sensor/component. Example: "OP E" : Open circuit or "CL O" : Closed circuit.
COMPONENT UNDER TEST
Number | Component |
|
|
02 | Interior Temperature Sensor |
|
|
04 | Exterior Temperature Sensor |
|
|
06 | Evaporator Temperature Sensor |
|
|
08 | Left Heater Core Temperature Sensor |
|
|
10 | Right Heater Core Temperature Sensor |
|
|
12 | Engine Coolant Temperature Sensor (ECT) |
|
|
14 | Left Temperature Selector Wheel Setting (Degree C) |
|
|
16 | Right Temperature Selector Wheel Setting (Degree C) |
|
|
18 | Vehicle Speed Signal(km/h) |
|
|
20 | Soft Top OPEN : "U", Soft Top CLOSED : "O" |
|
|
22 | Power Supply Voltage |
|
|
83 | OFF/ON (Not Used) |
|
|
84 | Blower Motor Voltage "050" (0.5v) - "600" (6.0v) |
|
|
FAULT DIAGNOSIS
1Turn temperature selector wheel into the white area.
2Place the air speed selector at position 0 and the air direction to "DOWN"
3IGNITION = ON : Position 1
4Within the next 10 sec., press the "RECIRCULATE AIR" and "REST" button simultaneously for 3 sec.
5Press the AUTO button until all error numbers are read and recorded.
84