6 - 7 HFM-SFI
CS1000 Code Scanner OB15-11
OB15 | MB | Description |
|
|
|
082 |
| Not used |
|
|
|
083 |
| Not used |
|
|
|
084 | (086) | Fuel purge |
|
|
|
085 | (087) | Fuel purge |
|
|
|
086 | (088) | Transmission shifting delay/smooth |
|
|
|
087 |
| Not used |
|
|
|
088 |
| Not used |
|
|
|
089 | (089) | Camshaft timing adjust actuator circuit short to positive |
|
|
|
090 | (090) | Camshaft timing adjust actuator open circuit or short to ground |
|
|
|
091 | (091) | EGR |
|
|
|
092 | (092) | EGR |
|
|
|
093 | (093) | Transmission overload protection switch short to ground |
|
|
|
094 | (094) | Transmission overload protection switch, circuit short or open |
|
|
|
095 | (095) | Transmission overload protection switch, circuit short or open |
|
|
|
096 | (096) | Transmission overload protection switch signal implausible |
|
|
|
097 | (097) | CAN problem Transmission communication from HFM control system faulty |
|
|
|
098 | (098) | CAN problem No data reception from ASR |
|
|
|
099 | (116) | CAN problem No data reception from IRCL. ( if equip with IRCL) Voltage supply at |
|
| Circuit 87M, low voltage or implausible (Starting 06/93) |
|
|
|
100 |
| Not used |
|
|
|
101 | (099) | CAN problem No data reception from EFP,TPM |
|
|
|
102 | (100) | CAN problem No data reception from Diagnosis Module |
|
|
|
103 |
| Not used |
|
|
|
104 | (117) | Attempt to start with IRCL locked |
|
|
|
105 | (101) | No starter signal (Terminal 50), open or short circuit |
|
|
|
106 | (102) | Thermocouple CAT B16/6 Temperature too high |
|
|
|
107 | (103) | Thermocouple CAT B16/6 Temperature too low |
|
|
|
108 | (104) | Fuel safety |
|
|
|
109 |
| Not used |
|
|
|
110 | (105) | Resonance intake manifold switchover valve, short to positive |
|
|
|
111 | (106) | Resonance intake manifold switchover valve, open circuit/short to ground |
|
|
|
112 | (107) | Ignition dwell angle control output stage, short to ground |
|
|
|
113 | (114) | HFM control unit identification illogical |
|
|
|
114 | (108) | Oxygen sensor heater (after/downstream of Cat. Conv.), short to positive |
|
|
|
115 | (109) | Oxygen sensor heater (after/downstream of Cat. Conv.), open circuit or short to |
|
| ground |
|
|
|
125