14 TROUBLESHOOTING
14.2Service Indicator Error Codes
For the following table, refer to FIGURE 6.1 on page 25.
FLASH | DESCRIPTION | MEANING |
1 | Battery Low | The batteries are running low. |
|
| • Recharge the batteries. |
2 | Low Battery Fault | The batteries have run out of charge. |
|
| • Recharge the batteries. |
3 | High Battery Fault | Battery voltage is too high. This may occur if overcharged &/or traveling down a long slope. |
|
| • If traveling down a slope, reduce your speed to minimize the amount of regenerative charging. |
|
| • Check the battery and associated connections and wiring. |
|
|
|
4 | Current Limit | The motor has been exceeding its maximum current rating for too long. This may be due to a faulty motor. |
|
| • Check the motor and associated connections and wiring. |
|
| • Turn the controller off, leave for a few minutes and turn back on again. |
5 | Park Brake Fault | Either a park brake release switch is active or the park brake is faulty. |
|
| • Check the park brake and associated connections and wiring. |
|
| • Ensure any associated switches are in their correct positions. |
6 | Throttle OONAPU | The Throttle is out of neutral when turning the controller on. |
|
| • Ensure the throttle is in neutral when turning the controller on. |
|
| • The Throttle may require |
|
|
|
7 | Speed Pot Fault | The throttle, speed limit pot, SRW or their associated wiring may be faulty. |
|
| • Check the throttle and speed pot and associated connections and wiring. |
8 | Motor Voltage Fault | The motor or its associated wiring is faulty. |
|
| • Check the motor and associated connections and wiring. |
9 | Other error | The controller may have an internal fault. |
|
| • Check all connections & wiring. |
10 | Push/Rollaway Fault | The scooter has exceeded the Push or Rollaway speed limits. |
|
| • Turn the controller off and then on again. |
Invacare® Lynx™ | 54 | Part No. 1143205 |