)2
60 | Roof "OPE" = OPEN, "CLO" = CLOSED |
|
|
61 | Left Air Outlet, Potentiometer Voltage |
|
|
62 | Vacuum Actuator 46, Feedback Potentiometer Voltage |
|
|
63 | Center Air Outlet, Potentiometer Voltage |
|
|
64 | Vacuum Actuator 47, Feedback Potentiometer Voltage |
|
|
65 | Right Air Outlet, Potentiometer Voltage |
|
|
66 | Vacuum Actuator 47, Feedback Potentiometer Voltage |
|
|
FAULT DIAGNOSIS
1.IGNITION : Position 1
2.Temperature selector wheel : "LO"
3.Within 20 seconds press the REST and DEFROST buttons simultaneously for more than 5 seconds.
4.The LED in the RECIRCULATE button flashes and "dI A" appears on the display.
5.Press the AUTO button until all DTC's are displayed and recorded.
6.The current faults are displayed first, then the intermittent faults. "END'" is displayed when all codes have been displayed.
7.To erase codes press AUTO again, "dEL" will be displayed. Press v and ^ simultaneously for more than 5 seconds. The display will then show
8.IGNITION : OFF to end the test program.
| FAULT CODES - 129 Chassis from 9/95 |
|
|
DTC Readout | Description |
|
|
026 | CAN Bus Communication |
|
|
226 | |
|
|
227 | Outside Air Temperature Sensor (B14) |
|
|
228 | Heater Core Temperature Sensor (B10/2) |
|
|
230 | Evaporator Temperature Sensor (B10/6) |
|
|
231 | Engine Coolant Temperature Sensor (B11/4) |
|
|
232 | Refrigerant Pressure Sensor (B12) |
|
|
233 | Refrigerant Temperature Sensor (B12/1) |
|
|
241 | Refrigerant Level |
|
|
416 | Coolant Circulation Pump (A31m1) |
|
|
417 | Automatic A/C Monovalve (Y19) |
|
|
419 | A/C Compressor Electromagnetic Clutch (A9k1) |
|
|
420 | Closed (Idle) Throttle Speed Increase |
|
|
91