Desa Tech CCL3018NR, CCL3930PRA Continued, Observed Problem, Possible Cause, Remedy

Models: CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA CCL3018NR CCL3930PRA

1 36
Download 36 pages 4.95 Kb
Page 25
Image 25
Press in control knob fully

TROUBLESHOOTING

 

 

Continued

 

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes

1. Control knob not fully pressed in

1.

Press in control knob fully

out when control knob is re-

2. Control knob not pressed in

2.

After ODS/pilot lights, keep

leased

 

long enough

 

control knob pressed in 30 sec-

 

 

 

 

onds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shutoff

 

 

fully open

 

valve

 

4.

Pilot flame not touching ther-

4.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing pi-

 

B) Clean ODS/pilot (see

 

 

lot flame to go out. This prob-

 

Cleaning and Maintenance,

 

 

lem could be caused by one or

 

page 23) or replace ODS/pi-

 

 

both of the following:

 

lot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

Burner does light after ODS/ 1. Burner orifice clogged pilot is lit

2. Inlet gas pressure is too low

3. Thermopile leads discon- nected or improperly con- nected

4. Burners will not come on in remote position

1.Clean burner (see Cleaning and Maintenance, page 23) or replace burner orifice

2.Contact local natural or pro- pane/LP gas company

3.Reconnect leads (see Wiring Diagram, page 32)

4.Replace battery in transmitter and receiver

Delayed ignition burner

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 23) or

 

 

 

 

replace burner orifice

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 23) or

 

 

 

 

replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

111161-01D

www.desatech.com

25

Page 25
Image 25
Desa Tech CCL3018NR, CCL3930PRA Continued, Observed Problem, Possible Cause, Remedy, Press in control knob fully