MINIMUM FIREPLACE CLEARANCE

INSTALLATION

Continued

TO COMBUSTIBLE MATERIALS WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

LOG SIZING REQUIREMENTS WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

 

Side Wall 16"

 

Ceiling: 42"

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

Minimum Firebox

 

Log

 

 

 

 

Front

Rear *

Size

 

Height

Depth

Width

Width

 

 

 

 

 

 

 

18"

 

17"

13"

 

28"

20"

24"

 

17"

13"

 

28"

21"

30"

 

17"

13"

 

34"

24"

 

 

 

 

 

 

 

* Measured at 13" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127- listed manufactured fireplace, or listed vent-free firebox.

Minimum Clearances for Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabi- net to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and pro- trudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fire- place opening (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B.Clearances from the top of the fireplace open- ing to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall

NOTICE: Manual control heaters may be used as a vented prod- uct. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace open- ing is not needed. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 11.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombus- tible material behind it. Noncombustible material must extend at least 8" up (for all models). If non- combustible material is less than 12", you must in- stall the fireplace hood accessory (24" and 30" mod- els only). See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chim- ney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.