OWNER’S MANUAL
FIREPLACE INSTALLATION
Continued
INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1
WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.
WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.
1.Open lower louver panel. The valve is attached to the underside of the fire- box assembly.
2.Disconnect from the valve the wires running from the ON/OFF switch.
3.Connect one terminal of 25 ft. wire for the wall thermostat to the TPTH termi- nal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the control valve as pictured in Figure 40. If wires are not connected as shown, the ther- mostat will not work.
4.Route the 25 ft. wire through openings provided on the sides of the fireplace to a convenient location to mount your thermostat (no outside wall).
IMPORTANT: The wire may be short- ened but must not be lengthened.
The thermostat should be mounted 54" above the floor in a location where there is good air circulation.Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.
5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.
6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 41).
WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire hazard will occur.
7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 42).
8.Install the base to the wall with screws provided with thermostat.
9.Move the temperature adjustment back and forth to insure the
10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)
11.Set the temperature adjustment to the desired setting.
This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.
To Wall
Thermostat
t
Figure 40 - Control Valve Terminals
Feed wires through rectangular slots
Figure 41 - Back View of Thermostat Base
| Terminal “W” |
W |
R
Terminal “R”
Figure 42 - Thermostat Base Terminals
WIRELESS HAND-HELD REMOTE CONTROL ACCESSORY - GHRCT
(Included)
Installing Battery into Receiver
1.Open bottom louver and locate the switch bracket on the left.
2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.
3.Locate the battery clip mounted on the back of the receiver. Slide a
4.Attach the terminal wires to the battery.
5.Replace the switch bracket.
Receiver
Terminal
Wires
Battery Clip
Figure 43- Attaching Battery to Receiver
Installing 9-Volt Battery in Hand- Held Remote Control Unit
1.Remove battery cover on back of re- mote control unit.
2.Attach terminal wires to a
3.Replace battery cover onto remote con- trol unit.
| Battery |
|
Terminal | Cover | Remote |
| ||
Wires |
| Control Unit |
|
| |
Battery |
|
|
|
| Battery |
|
| Housing |
Figure 44 - Installing Battery in Hand- Held Remote Control Unit
Continued
104605 | 21 |