Desa Tech CHDV37P Hand-Heldremote Operation, Operating Optional Blower Accessory, Continued

Models: CHDV37P CHDV41N CHDV37N CHDV41P

1 38
Download 38 pages 2.33 Kb
Page 26
Image 26
HAND-HELD REMOTE

OPERATINGManual backgroundManual background CHDV37N/P AND CHDV41N/P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

OPERATING

FIREPLACE

Continued

HAND-HELD REMOTE

OPERATION

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions. page 25.

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON posi-

tion. Turn variable control knob any-

where between HI and LO. Slide the

In auto mode, the room tempera- ture is controlled by the thermo- stat in the hand-held remote con- trol unit. To increase the room tem- perature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom ar- row of the TEMP button. At higher settings the heater will run more. IMPORTANT: The hand-held re- mote control unit must be near the heater but not extremely close to it. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used.

Blower Control Knob

Variable

(Optional Accessory)

Control Knob

 

4.To turn the burners off when oper- ating in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the gas control knob on the heater to the OFF position or set selector switch to OFF position.

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

Both the GA3750 manual blower and the CDA3620T thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

selector switch to the REMOTE posi-

tion. Note: The burner(s) may light

if hand-held remote ON button was

on when selector switch was last

turned off.

You can now turn the burners on and

off with the hand-held remote control

OFF

ON

REMOTE

OFF

ON

Selector Switch in Remote Position

N

 

L

 

O

 

O

I

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

Gas Control

Knob in ON

Position

Note for CDA3620T Only: If you are using CDA3620T blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox

unit.

IMPORTANT: Do not leave the selec-

tor switch in the REMOTE position

when the pilot is not lit. This will drain

the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

Figure 54 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

remote control unit for up to 3 sec-

onds to assure proper operation.

2. Select the MAN (manual) or AUTO

button on the hand-held remote con-

trol unit (see Figure 55).

In manual mode, turn burners on

or off by pressing the ON/OFF but-

tons on the hand-held remote con-

trol unit.

Shows Temperature Setting

Allows Burner(s) to be Turned On and Off with the Hand- Held Remote Unit.

The Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

Figure 55 - Hand-Held Thermostat Remote Control Unit Selections (GHRCT)

26

104605

Page 26
Image 26
Desa Tech CHDV37P Hand-Heldremote Operation, Operating Optional Blower Accessory, CHDV37N/P AND CHDV41N/P, Continued