F212

 

F213

 

 

 

RR Input Point 2 Setting

Direct Access Number —

F212

Program Frequency Speed Reference Setpoints

Parameter Type — Numerical

This parameter is used to set the gain and bias of the RR input terminal when

Factory Default — 100

 

Changeable During Run — Yes

the RR terminal is used as the control input while operating in the Speed

 

 

Control mode or the Torque Control mode.

Minimum — 0

 

This parameter sets the RR input level that is associated with RR Input Point 2

Maximum — 100

 

Frequency when operating in the Speed control mode or is associated with the

Units — %

 

RR Input Point 1 Rate when operating in the Torque Control mode.

 

 

 

This value is entered as 0% to 100% of the RR input signal range.

 

 

See RR Input Point 1 Setting for more information on this setting when used

 

 

for Speed control.

 

 

See RR Input Point 1 Rate for more information on this setting when used for

 

 

Torque Control.

 

 

 

 

 

RR Input Point 2 Frequency

Direct Access Number —

F213

Program Frequency Speed Reference Setpoints

Parameter Type — Numerical

This parameter is used to set the gain and bias of the RR input terminal when

Factory Default — 60.00

 

Changeable During Run — Yes

the RR terminal is used as the control input while operating in the Speed

 

 

Control mode.

Minimum — 0.00

 

This parameter sets RR Input Point 2 Frequency and is the frequency that is

Maximum — Max. Freq. (F011)

associated with the setting of RR Input Point 2 Setting when operating in the

Units — Hz

 

 

 

Speed Control mode.

See RR Input Point 1 Setting for more information on this setting.