9 — Option V/I

This setting allows for the use of the optional voltage/current frequency-control interface.

10 — UP/DOWN Frequency

A discrete terminal may be configured to increase or decrease the speed of the motor by momentarily connecting the assigned terminal to CC. See F264 on pg. 128 for further information on this feature.

11 — Pulse Input Option

This setting is used to allow the system to use a pulsed input for frequency control. See PG Input Point 1 Setting on pg. 122 for further information on this feature.

12 — Pulse Input (motor CPU)

This setting is used to allow the system to use a pulsed input for frequency control. See PG Input Point 1 Setting on pg. 122 for further information on this feature.

13 — Binary/BCD Input Option

Allows for discrete terminal to be used for frequency-control input.

40

H9 ASD Installation and Operation Manual

Page 48
Image 48