F330

 

F334

 

 

 

 

Automatic Light-Load High-Speed Operation Frequency

Direct Access Number —

F330

Program Special Crane/Hoist Settings

Parameter Type — Numerical

This parameter establishes the speed to which the ASD will ramp when

Factory Default — 60.00

 

 

Changeable During Run — No

operating in the Light-LoadHigh-Speedmode.

 

 

 

 

Minimum — 30.00

 

 

 

Maximum — Upper Limit (F012)

 

Units — Hz

 

 

 

 

 

 

Light-Load High-Speed Operation Switching Lower-Limit

Direct Access Number —

F331

Frequency

Parameter Type — Numerical

Program Special Crane/Hoist Settings

Factory Default — 40.00

 

 

This parameter sets an output frequency threshold that, once surpassed, allows

Changeable During Run — Yes

Minimum — 30.0

 

 

the Light-LoadHigh-Speedfunction to be used.

 

 

The Light-LoadHigh-Speedfunction may be used if the frequency threshold

Maximum — Upper Limit (F012)

 

 

 

set at this parameter and the following conditions are met:

Units — Hz

 

 

1) Light-Load High-Speed Operation Enable is configured at F328.

 

 

 

2) The output torque is less than the setting established in F335 when reaching

 

 

 

the frequency setting here.

 

 

 

 

 

 

 

Light-Load High-Speed Operation Load Wait Time

Direct Access Number —

F332

Program Special Crane/Hoist Settings

Parameter Type — Numerical

After the time setting of F333 times out, this parameter determines the length of

Factory Default — 0.5

 

 

Changeable During Run — Yes

time that the Light-LoadHigh-Speedcriteria must be met until the Light-

 

 

 

Load High-Speedfunction engages.

Minimum — 0.0

 

 

 

Maximum — 10.0

 

 

 

Units — Seconds

 

 

 

 

 

 

Light-Load High-Speed Operation Detection Time

Direct Access Number —

F333

Program Special Crane/Hoist Settings

Parameter Type — Numerical

This parameter determines the length of time that the load requirement must

Factory Default — 1.0

 

 

Changeable During Run — Yes

meet the Light-Load High-Speed criteria before the Light-Load High-Speed

 

 

 

Enable (F328) is recognized.

Minimum — 0.0

 

 

Once recognized, the timer setting of F332 must expire to engage the Light-

Maximum — 10.0

 

 

 

 

 

Load High-Speed function.

Units — Seconds

 

 

 

 

 

 

Light-Load High-Speed Operation Heavy-Load Detection

Direct Access Number —

F334

Time

Parameter Type — Numerical

Program Special Crane/Hoist Settings

Factory Default — 0.5

 

 

While operating in the Light-LoadHigh-Speedmode, this parameter

Changeable During Run — Yes

Minimum — 0.0

 

 

determines the length of time that a load exceeding the Light-Load High-

 

 

Speed operation criteria may exist before the Light-LoadHigh-Speedmode is

Maximum — 10.0

 

 

terminated and normal operation resumes.

Units — Seconds

 

 

 

 

 

H9 ASD Installation and Operation Manual